4.6 Article

CMR DENSE and the Seattle Heart Failure Model Inform Survival and Arrhythmia Risk After CRT

期刊

JACC-CARDIOVASCULAR IMAGING
卷 13, 期 4, 页码 924-936

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jcmg.2019.10.017

关键词

cardiac magnetic resonance; cardiac resynchronization therapy; heart failure; implantable cardioverter-defibrillator; risk models

资金

  1. National Institutes of Health [R56 HL135556]
  2. Medtronic
  3. Siemens Healthineers
  4. Biosense Webster
  5. Boston Scientific
  6. CardioFocus
  7. St. Jude Medical
  8. Cook Medical

向作者/读者索取更多资源

OBJECTIVES This study sought to determine if combining the Seattle Heart Failure Model (SHFM-D) and cardiac magnetic resonance (CMR) provides complementary prognostic data for patients with cardiac resynchronization therapy (CRT) defibrillators. BACKGROUND The SHFM-D is among the most widely used risk stratification models for overall survival in patients with heart failure and implantable cardioverter-defibrillators (ICDs), and CMR provides highly detailed information regarding cardiac structure and function. METHODS CMR Displacement Encoding with Stimulated Echoes (DENSE) strain imaging was used to generate the circumferential uniformity ratio estimate with singular value decomposition (CURE-SVD) circumferential strain dyssynchrony parameter, and the SHFM-D was determined from clinical parameters. Multivariable Cox proportional hazards regression was used to determine adjusted hazard ratios and time-dependent areas under the curve for the primary endpoint of death, heart transplantation, left ventricular assist device, or appropriate ICD therapies. RESULTS The cohort consisted of 100 patients (65.5 [interquartile range 57.7 to 72.7] years; 29% female), of whom 47% had the primary clinical endpoint and 18% had appropriate ICD therapies during a median follow-up of 5.3 years. CURE-SVD and the SHFM-D were independently associated with the primary endpoint (SHFM-D: hazard ratio: 1.47/SD; 95% confidence interval: 1.06 to 2.03; p = 0.02) (CURE-SVD: hazard ratio: 1.54/SD; 95% confidence interval: 1.12 to 2.11; p = 0.009). Furthermore, a favorable prognostic group (Group A, with CURE-SVD <0.60 and SHFM-D <0.70) comprising approximately one-third of the patients had a very low rate of appropriate ICD therapies (1.5% per year) and a greater (90%) 4-year survival compared with Group B (CURE-SVD >= 0.60 or SHFM-D >= 0.70) patients (p = 0.02). CURE-SVD with DENSE had a stronger correlation with CRT response (r = -0.57; p < 0.0001) than CURE-SVD with feature tracking (r = -0.28; p = 0.004). CONCLUSIONS A combined approach to risk stratification using CMR DENSE strain imaging and a widely used clinical risk model, the SHFM-D, proved to be effective in this cohort of patients referred for CRT defibrillators. The combined use of CMR and clinical risk models represents a promising and novel paradigm to inform prognosis and device selection in the future. (C) 2020 by the American College of Cardiology Foundation.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据