4.7 Article

Potential formation of PCDD/Fs in triclosan wastewater treatment: An overall toxicity assessment under a life cycle approach

期刊

SCIENCE OF THE TOTAL ENVIRONMENT
卷 707, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.scitotenv.2019.135981

关键词

Emerging pollutants; Life Cycle Assessment; Electrochemical oxidation (EOX); Polychlorinated dibenzo-p-dioxins/furans (PCDD/Fs); EPA method; Toxicity

资金

  1. Spanish Ministry of Economy and Competitiveness (MINECO) [CTM2017-87740-R, CTM2016-76176-C2-1-R]
  2. FPI grant [BES-2015-072920, PRE2018-083526]
  3. Direccion General de Investigacion (DGI) [636]
  4. Direccion Academica de Relaciones Internacionales (DARI) from the Pontificia Universidad Catolica del Peru (PUCP)

向作者/读者索取更多资源

Wastewater may contain a diverse group of unregulated pollutants known as emerging pollutants, such as pharmaceuticals and personal care products (PPCPs). Triclosan (TCS) is a personal care product widely used as an antiseptic or preservative in cosmetics, hand wash, toothpaste and deodorant soaps. Advanced oxidation processes (AOPs) have been used as effective and alternative treatments for complex wastewater. However, an important criterion for the assessment of AOPs and their operation conditions could be the potential formation of new toxic secondary products, such as polychlorinated dibenzo-p-dioxins and furans (PCDD/Is), especially when emerging pollutants are present in the media. If these are omitted from environmental management studies, the real environmental impacts of a WWIPs (wastewater treatment plants) may be underestimated. Consequently, the current study aims to evaluate the environmental impacts derived from electrooxidation (EOX), one of the most effective oxidation technologies, of emerging pollutants using Life Cycle Assessment. The analyses were performed for the treatment of effluents containing TCS, firstly without considering the formation of PCDD/Fs and, thereafter, considering the effects of these compounds. Total toxicity, calculated through different methods and corresponding impact factors, were evaluated for each stage of the process when different electrolytes are used, including PCDD/Fs formation. Finally, a sensitivity analysis was carried out to study i) the effect of the TCS initial concentration on the environmental impacts associated to ecotoxicity for the different life cycle methods and ii) the influence of changing the organic pollutant on PCDD/Fs formation employing 2-chlorophenol (2-CP). As a result, LCIA methods demonstrate that they are not fully adapted to the computation of PCDD/Fs in the water compartment, since only 2,3,7,8-tetraclorodibenzo-p-dioxina (2,3,7,8-TCDD) is present as a substance in the impact categories assessed, ignoring the remaining list of PCDD/Fs. (C) 2019 Elsevier Q.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据