4.7 Article

Boosting Cr(VI) detoxification and sequestration efficiency with carbon nanotube electrochemical filter functionalized with nanoscale polyaniline: Performance and mechanism

期刊

SCIENCE OF THE TOTAL ENVIRONMENT
卷 695, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.scitotenv.2019.133926

关键词

Cr(VI); Polyaniline; Carbon nanotubes; Electroactive filter; Detoxification; Sequestration

资金

  1. Fundamental Research Funds for the Central Universities [2232019G-11]
  2. Open Research Fund Program of Key Laboratory of Cleaner Production and Integrated Resource Utilization of China National Light Industry [CP-2019-ZD1]
  3. Natural Science Foundation of Shanghai, China [18ZR1401000]
  4. National Key Research and Development Program of China [2018YFF0215703]
  5. Shanghai Pujiang Program [18PJ1400400]

向作者/读者索取更多资源

Being able to simultaneously reduce and adsorb highly toxic Cr(VI) from bodies of water would provide a significant advance in the treatment of water pollution. Herein, we report on the design of an electroactive filter consisting of nanoscale polyaniline modified carbon nanotubes (PANI-CNT). In an electric field, both Cr(VI) reduction kinetics and Cr(III) sorption capacity were enhanced as the flow rate and voltage increased. At pH 7, Cr(VI) removal efficiency increased from 29.3% at 0 V to 70.2% at 2.5 V. This can be ascribed to superior electrical conductivity, more available active sites and limited pore size of the PANI-CNT filter, further boosted by the flow-through operation. Due to convection-enhanced mass transport, the proposed continuous-flow PANI-CNT filter demonstrated an evidently enhanced kinetic process when compared to conventional batch system. Various advanced assessments and density functional theory calculations verified the essential role of the electric field during Cr(VI) removal. Scanning transmission electron microscopy (STEM) examinations showed that the Cr was mainly sequestered by the PANI. It was also confirmed that an exhausted PANI-CNT filter can be regenerated by chemical washing with an HCl solution. Experiments with actual Cr(VI)-contaminated electroplating wastewater further verified the effectiveness of the system, with complete Cr(VI) transformation and a 50% Cr-total removal efficiency at 2.5 V with a flow rate of 3 mL/min. This study provides new insights into practical continuous-flow solutions to the effective removal of highly toxic Cr(VI). (C) 2019 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据