4.7 Article

Long-duct forced and short-duct exhaust ventilation system in tunnels: Formation and dust control analysis of pressure ventilation air curtain

期刊

PROCESS SAFETY AND ENVIRONMENTAL PROTECTION
卷 132, 期 -, 页码 367-377

出版社

ELSEVIER
DOI: 10.1016/j.psep.2019.10.012

关键词

Long-duct forced and short-duct exhaust ventilation system; Tunnel; Pressure ventilation air curtain; Dust control; Eddy airflow field

资金

  1. National Key R&D Program of China [2017YFC0805201]
  2. National Natural Science Foundation of China [51874191, 51404147]
  3. Focus on Research and Development Plan in Shandong Province [2017GSF20111]
  4. Open Fundation for Key Laboratory of College of Mining and Safety Engineering, Shandong University of Science and Technology [MDPC201705]
  5. Graduate Science and Technology Innovation Project [SDKDYC190346]

向作者/读者索取更多资源

To decrease the high concentration dust in tunnels with a long-duct forced and short-duct exhaust ventilation system, airflow and dust field migration behaviours, when different distances between pressure ventilation outlet and tunnel face are involved, are analysed with the application of numerical simulation and field measurements in this study. The formation principle of air curtain and the dust control rule in tunnels with a long-duct forced and short-duct exhaust ventilation system are also elaborated and the conclusions can provide the guidance for dust control in tunnels. Numerical simulation shows that the formation of pressure ventilation air curtain is mainly determined by the distance between the pressure ventilation outlet in eddy airflow field and tunnel face. The mathematical relationship of the diffusion distance of high concentration dust is determined as a function of the distance between the pressure ventilation outlet and tunnel face. Field measurements are carried out in the second auxiliary tunnel of Longgu to determine the dust concentration along the tunnel. The results show that when the distance between the pressure ventilation outlet and tunnel face is 35 m, the dust concentration is lowered to less than 18.2 mg/m(3), demonstrating the effective dust control of the pressure ventilation air curtain. It also ensures the safety of tunnel production and the protection of the workers' physical health, and reduces the occurrence of pneumoconiosis. (C) 2019 Institution of Chemical Engineers. Published by Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据