4.7 Article

A comparative study of two graphene based elastomeric composite sensors

期刊

POLYMER TESTING
卷 80, 期 -, 页码 -

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.polymertesting.2019.106106

关键词

Graphene; Epoxy; PDMS rubber; Flexible sensor

资金

  1. Asbury (Asbury, NJ, USA) [1395]
  2. National Natural Science Foundation of China [51973123]
  3. Natural Science Foundation of Liaoning Province [2019-MS-256]
  4. Aeronautical Science Foundation of China [2018ZF54036]
  5. China Postdoctoral Science Foundation [2019M651151]
  6. National Health and Medical Research Council Early Career Fellowship [1112258]
  7. National Health and Medical Research Council of Australia [1112258] Funding Source: NHMRC

向作者/读者索取更多资源

Flexible and stretchable multifunctional electronics is expected to be one of the most active research areas in the next decade. In this work, we fabricate graphene based flexible film sensors using two different matrices; polydimethylsiloxane (PDMS) and epoxy. A graphene platelet (GnP) refers to a nanosheet that consists of a few stacked graphene layers, mostly below similar to 10 nm in thickness. The mechanical, electrical and thermal properties of the fabricated composite films were evaluated. The morphology showed a good dispersibility of GnPs into the PDMS and epoxy matrices. The percolation threshold for GnP/PDMS and GnP/epoxy composite film was achieved at 3.19 vol% and 1.08 vol%, respectively. The fabricated composite films showed improvements in thermal conductivity for GnP/PDMS and GnP/epoxy composite film by 147% and 444%, respectively. The Young's modulus for GnP/epoxy system showed a significant increase by 1344% as compared to GnP/PDMS system, whose increment was by 144%. Upon pressure implication, bending and torsional deformation, GnP/PDMS system demonstrated a better electrical response and flexibility and simultaneously, showed a good stretchability by producing maximum strain up to 25%. The GnP/PDMS system is sensitive to temperature in a wide temperature range (- 25 degrees C-163 degrees C), and is more suitable as a temperature sensor in cryogenic and high temperature environment than GnP/epoxy system. On the other hand, the GnP/epoxy produced higher repeatability during fatigue testing, emphasizing that GnP/epoxy composite films are highly durable as a strain sensor. This research has enlightened on the importance of selecting the optimum matrix, which is a key factor that determines the overall superior functionality of a flexible sensor.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据