4.6 Article

A deep learning method for producing ventilation images from 4DCT: First comparison with technegas SPECT ventilation

期刊

MEDICAL PHYSICS
卷 47, 期 3, 页码 1249-1257

出版社

WILEY
DOI: 10.1002/mp.14004

关键词

4DCT ventilation imaging; deep learning; SPECT validation

资金

  1. National Natural Science Foundation of China [11905295, 81502649, 11875320]
  2. Beijing Hope Run Special Fund of Cancer Foundation of China [LC2018B07]
  3. Natural Science Foundation of Beijing Municipal [7204295]

向作者/读者索取更多资源

Purpose The purpose of this study is to develop a deep learning (DL) method for producing four-dimensional computed tomography (4DCT) ventilation imaging and to evaluate the accuracy of the DL-based ventilation imaging against single-photon emission-computed tomography (SPECT) ventilation imaging (SPECT-VI). The performance of the DL-based method is assessed by comparing with density change- and Jacobian-based (HU and JAC) methods. Materials and methods Fifty patients with esophagus or lung cancer who underwent thoracic radiotherapy were enrolled in this study. For each patient, 4DCT scans paired with 99mTc-Technegas SPECT/CT were acquired before the first radiotherapy treatment. 4DCT and SPECT/CT were first rigidly registered using MIMvista and converted to data matrix using MATLAB, and then transferred to a DL model based on U-net for correlating 4DCT features and SPECT-VI. Two forms of 4DCT dataset [(a) ten phases and (b) two phases of peak-exhalation and peak-inhalation] as input are studied. Tenfold cross-validation procedure was used to evaluate the performance of the DL model. For comparative evaluation, HU and JAC methodologies are used to calculate specific ventilation imaging based on 4DCT (CTVI) for each patient. The voxel-wise Spearman's correlation was evaluated over the whole lung between each of CTVI and corresponding SPECT-VI. The SPECT-VI and produced CTVIs were segmented into high, median, and low functional lung (HFL, MFL, and LFL) regions. The spatial overlap of corresponding HFL, MFL, and LFL for each CTVI against SPECT-VI was also evaluated using the dice similarity coefficient (DSC). The averaged DSC of functional lung regions was calculated and statistically analyzed with a one-factor ANONA model among different methods. Results The voxel-wise Spearman r(s) values were (0.22 +/- 0.31), (-0.09 +/- 0.18), and (0.73 +/- 0.16)/(0.71 +/- 0.17) for the CTVIHU, CTVIJAC, and CTVIDL(1)/CTVIDL(2). These results showed the DL method yielded the strongest correlation with SPECT-VI. Using the DSC as the spatial overlap metric, we found that the CTVIHU, CTVIJAC, and CTVIDL(1)/CTVIDL(2) methods achieved averaged DSC values for all patients to be (0.45 +/- 0.08), (0.33 +/- 0.04), and (0.73 +/- 0.09)/(0.71 +/- 0.09), respectively. The results demonstrated that the DL method yielded the highest similarity with SPECT-VI with the prominently significant difference (P < 10(-7)). Conclusions This study developed a DL method for producing CTVI and performed a validation against SPECT-VI. The results demonstrated that DL method can derive CTVI with greatly improved accuracy in comparison to HU and JAC methods. The produced ventilation images can be more accurate and useful for lung functional avoidance radiotherapy and treatment response modeling.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据