4.4 Article

Reliability and validity analyzes of Kinect V2 based measurement system for shoulder motions

期刊

MEDICAL ENGINEERING & PHYSICS
卷 76, 期 -, 页码 20-31

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.medengphy.2019.10.017

关键词

Shoulder pose; Reliability; Validity; Kinect V2; Measurement

资金

  1. Bilecik Seyh Edebali University Coordinating Unit of Scientific Research Projects [2017-01.BSEU.03-04]

向作者/读者索取更多资源

Telerehabilitation systems provide some advantages against the classic rehabilitation methods. The ability of the shoulders depends on active motion range of them to do activities in daily life and to do sports. To evaluate the shoulder motions, range of motion (ROM) measurement is a basic method. Clinical goniometer and digital goniometer are the most commonly used measurement tools. However, these measurement tools have some deficiencies and difficulties. In this paper, we consider a Kinect One Sensor (Kinect V2) based measurement system for shoulder motions as an alternative method. The aim of this study is to examine the reliability and validity analyzes of the proposed shoulder measurement system. Three systems were used to evaluate validity of the Kinect V2 to measure shoulder motions: Kinect V2 based system, clinical goniometer and digital goniometer. One expert physical therapist measured shoulder abduction, flexion, external rotation, internal rotation and extension ROM values using a clinical goniometer and a digital goniometer in 40 healthy volunteers (22 males, 18 females, and 19-33 years old). All poses for each shoulder motion were captured with the Kinect V2 based system again and the ROM values were calculated. These procedures were carried out with all of the volunteer participants in three repetitions. In reliability for Kinect V2 based shoulder motion measurement system, we used the intraclass correlation coefficients (ICC), standard error of the measure (SEM), minimal detectable change (MDC). The validity test includes the 95% limits of agreement (LOA) and mean difference between the Kinect V2 based system and the both of the goniometer systems for measuring shoulder motions. The high ICC values show that the Kinect V2 based shoulder motion measurement system has very good intra-rater reliability for abduction, flexion, external rotation, internal rotation shoulder poses. For extension pose, it has good reliability result according to the ICC value. The validity analysis gives good results for all shoulder poses except internal rotation between Kinect V2 and clinical/digital goniometer. As a result, Kinect V2 based measurement system is a reliable and valid alternative telerehabilitation tool for shoulder motions. (C) 2019 IPEM. Published by Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据