4.5 Article

Neutron MIEZE spectroscopy with focal length tuning

期刊

MEASUREMENT SCIENCE AND TECHNOLOGY
卷 31, 期 3, 页码 -

出版社

IOP PUBLISHING LTD
DOI: 10.1088/1361-6501/ab5358

关键词

MIEZE; neutron spin echo; field subtraction coil

资金

  1. BMBF [Forderkennzeichen 05K16WO6]

向作者/读者索取更多资源

We report on a method to tune the focal length of high resolution neutron MIEZE spectrometers. The MIEZE technique relies on a fast sinusoidal neutron intensity modulation up to the MHz range, generated by the rotation of the neutron spin in radio-frequency spin flippers, and subsequent conversion to an intensity modulation by a spin analyzer. This intensity modulation is washed out due to the neutron velocity dispersion, but by proper choice of the spin rotation frequencies as well as the distances between sample, detector and spin flippers, a focal point in space appears (echo point), where the neutron detector is placed. In this work, we describe how to extend the dynamic range of the MIEZE technique by several orders of magnitude by introducing a field subtraction coil (NSE coil), such that at low energy resolution a good overlap with conventional spectroscopy techniques is achieved. All formulas for calculating the tuning parameters and an experimental example from the RESEDA spectrometer at the Heinz Maier-Leibnitz Zentrum (MLZ) are discussed.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据