Effects of immediately static loading on osteointegration and osteogenesis around 3D-printed porous implant: A histological and biomechanical study

出版社

ELSEVIER
DOI: 10.1016/j.msec.2019.110406

关键词

Selective laser melting; Porous implant; Mechanical loading; Osteointegration; Osteogenesis

资金

  1. National Natural Science Foundation of China [11872135, 3100690]
  2. Program for Innovation Team Building at Institutions of Higher Education in Chongqing in 2016
  3. Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education
  4. Medical Scientific Nurture Research of the Stomatological Hospital of Chongqing Medical University [PYM201605]
  5. Chongqing Science and Technology Bureau New High-end RD Institution [CSTC2018(C)XXYFJG0004]

向作者/读者索取更多资源

The 3D-printed porous implant is capable of achieving favorable osteointegration and osteogenesis in the absence of mechanical stimulation during the early healing period. The purpose of this study is to evaluate the impact of immediately static loading on bone osteointegration and osteogenesis around the 3D-printed porous implant. Thirty porous implants with optimal configuration were installed bilaterally into femurs of 15 rabbits. The Load group on the left side was applied the maximal initial load of 10 N offered by a diminutive and built-in loading device and the Non-load group was on the contralateral side. At 2, 4, and 8 weeks post-operatively, the explants were harvested for push-out test to measure the biological fixation strength. The quantity and quality of new bone were evaluated by the means of histological examination, Micro-CT and bone density analysis. Moreover, the animal data were integrated into finite element models to assess the biomechanics of pefi-implant bone. The results indicated that the quantity, quality and biomechanical properties of the new bone increased and optimized along with the healing time. It also demonstrated that the immediately static loading increased the volume of new bone with inferior quality in 2 weeks after implantation and the adverse influence emerged gradually as time extended. Moreover, finite element results demonstrated that the early structures of new bone around porous implant were not suitable for functional loading. This study indicated the mineralization modes of distance osteogenesis and contact osteogenesis around the porous implant. Accordingly, the delay and progressive loading protocol was recommended.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据