4.6 Article

Development, validation and application of LC-MS/MS method for quantification of amino acids, kynurenine and serotonin in human plasma

出版社

ELSEVIER
DOI: 10.1016/j.jpba.2019.113018

关键词

LC MS/MS; Amino acid; Serotonin; Kynurenine; Fit-for-purpose validation; Surrogate matrix

资金

  1. Hungarian Brain Research Program [KTIA_NAP_13-2-2015-0001, 2017-1.2.1-NKP-2017-00002]
  2. Hungarian Academy of Sciences (MTA-SE Neuropsychopharmacology and Neurochemistry Research Group)
  3. New National Excellence Program of the Ministry of Human Capacities [UNKP-18-2-1-SE-86]
  4. Higher Education Institutional Excellence Programme of the Ministry of Human Capacities in Hungary, within Semmelweis University

向作者/读者索取更多资源

Altered serotonergic neurotransmission is a key factor in several neurologic and psychiatric disorders such as migraine. Human and animal studies suggest that chronically low interictal serotonin levels of plasma and brain may facilitate increased activity of the trigeminovascular pathway, and may contribute to development of repeated migraine attacks. However, brain serotonin synthesis is affected by the concentration of tryptophan, its metabolites and a number of amino acids. In this work a simple and robust LC-MS/MS method for the quantitative determination of valine, leucine, isoleucine, phenylalanine, tyrosine, tryptophan, serotonin and kynurenine in human plasma has been developed and validated. Sample preparation was achieved by protein precipitation, using trifluoroacetic acid. Chromatographic separation was carried out on a Supelco Ascends (R) Express C18 column (3.0 mm i.d. x 150 mm, 2.7 mu m) equipped with an Agilent Zorbax Eclipse XDB C8 guard-column under isocratic conditions at a flow rate of 0.4 mL/min, over a 6.5 min run time. Mobile phase was 0.2% trifluoroacetic acid - acetonitrile (85:15, v/v). The eight analytes and two internal standards were ionized by positive electrospray ionization and detected in multiple reaction monitoring mode. A fit-for-purpose validation approach was adopted using surrogate matrix for the preparation of calibration samples. The calibration curves of all analytes showed excellent linearities with a correlation coefficient (r(2)) of 0.998 or better. Spiked surrogate matrix samples and pooled human plasma were used as quality control samples. Intra-day and inter-day precisions were less than 11.8% and 14.3%, and accuracies were within the ranges of 87.4-114.3% and 87.7-113.3%, respectively. Stability of the components in standard solutions, surrogate matrix, pooled plasma and processed samples were found to be acceptable under all relevant conditions. No significant carryover effect was observed. The surrogate matrix behaved parallel to human plasma when assessed by standard addition method and diluting the authentic matrix with surrogate matrix. The method was successfully applied for analysis of 800 human plasma samples to support a clinical study. (C) 2019 The Authors. Published by Elsevier B.V.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据