4.5 Article

Thermal performance evaluation of subcritical organic Rankine cycle for waste heat recovery from sinter annular cooler

期刊

出版社

SPRINGER
DOI: 10.1007/s42243-019-00355-2

关键词

Sinter; Waste heat recovery; Organic Rankine cycle; Fluid selection; Performance evaluation

向作者/读者索取更多资源

The sinter cooling flue gas expelled from the end of an annular cooler was taken as the heat source of an organic Rankine cycle (ORC) system, and R123, R245fa, R600, R601 and R601a were selected as the working fluids of the ORC system. The effects of evaporation temperature and superheat degree of working fluid, as well as the pinch point temperature difference in the evaporator on the system thermal performance, were analyzed in detail. The results show that the system net output power and exergy efficiency for different working fluids first increase and then decrease with an increase in the evaporation temperature and decrease with an increase in the superheat degree and pinch point temperature difference. The change in pinch point temperature difference has no effect on the system thermal efficiency. For a given operational condition, the system thermal efficiency and exergy efficiency of R123 are the maximum, while the system total irreversible loss of R245fa is the maximum. When the evaporation temperature is greater than 110 degrees C, the system net output power of R600 is the maximum. The ORC system could obtain the maximum net output power and exergy efficiency through the adjustment of evaporation temperature of working fluid.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据