4.6 Review

Factors associated with diagnostic accuracy, technical success and adverse events of endoscopic ultrasound-guided fine-needle biopsy: A systematic review and meta-analysis

期刊

JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY
卷 35, 期 8, 页码 1264-1276

出版社

WILEY
DOI: 10.1111/jgh.14999

关键词

adverse event rate; diagnostic accuracy rate; FNB; technical success rate

资金

  1. Natural Science Foundation of Guangdong Province [2018A0303100024]
  2. Three Engineering Training Funds in Shenzhen [SYLY201718, SYJY201714, SYLY201801]
  3. Technical Research and Development Project of Shenzhen [JCYJ20150403101028164]
  4. National Natural Science Foundation of China [81502040]
  5. Shenzhen Health Planning Commission [SZXJ2017030]

向作者/读者索取更多资源

Background and Aim Endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) is used to diagnose lesions within or adjacent to the digestive tract. However, there is no report on the overall diagnostic accuracy, technical success, and adverse events of FNB. The aims of this study were to conduct a systematic review and meta-analysis to comprehensively assess the diagnostic accuracy, technical success, and adverse events of FNB. Methods Pubmed, Embase, and Cochrane Library databases were searched for relevant articles published in English from January 1998 to May 2019 (No. CRD42019141647). Primary outcomes were EUS-FNB related diagnostic accuracy rate, technical success rate, and adverse event rate. Results A total of 51 articles including 5330 patients met our criteria. The overall EUS-FNB related diagnostic accuracy rate, technical success rate, and adverse event rate was 90.82% [95% confidence interval (CI) 88.69-92.76%], 99.71% [95% CI 99.35-99.93%], and 0.59% [95% CI 0.29-1.0%], respectively. Biopsy with 22G needle could increase the diagnostic accuracy rate and technical success rate to 92.17% [95% CI 89.32-94.61%] and 99.88% [95% CI 99.64-99.99%], respectively, and decrease the adverse event to 0.37% [95% CI 0.08-0.87%]. Moreover, it showed that 22G needle was an independent factor associated with a higher diagnostic accuracy rate and technical success rate and a lower adverse event rate (P = 0.04, P < 0.001, and P = 0.04, respectively) by univariate and multivariate meta-regression analyses. Conclusion Endoscopic ultrasound-guided fine-needle biopsy is a feasible and safe procedure for lesions within or adjacent to the digestive tract. Biopsy using 22G needle could increase the diagnostic accuracy rate and technical success rate and decrease adverse event rate during the FNB procedure.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据