4.6 Article

Clinical behavior of second-generation zirconia monolithic posterior restorations: Two-year results of a prospective study with Ex vivo analyses including patients with clinical signs of bruxism

期刊

JOURNAL OF DENTISTRY
卷 91, 期 -, 页码 -

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.jdent.2019.103229

关键词

Dental prosthesis; Zirconia; Computer-Aided design/Computer-Aided manufacturing; Wear

向作者/读者索取更多资源

Objectives: This study aimed to investigate (1) clinical outcomes of second-generation zirconia restorations, including patients with bruxism clinical signs, and (2) the material wear process. Methods: A total of 95 posterior monolithic zirconia tooth-elements in 45 patients were evaluated, 85 on implants and 10 on natural teeth, and 20.3% of restorations being fixed partial dentures (FPDs). Occlusal contact point areas were determined and half of those areas were left unglazed and just polished. Restorations were clinically evaluated following criteria of the World Dental Federation and antagonistic teeth were examined at each evaluation time. Wear ex vivo analyses using SEM and 3D laser profilometry were performed at baseline and after 6 months, 1 year, and 2 years respectively, temporarily removing the prostheses. Results: The Kaplan-Meier survival rate of restorations was 93.3% (100% for FPDs) and the success rate was 81.8%, with 4 abutment debondings, 3 tooth-supported crown debondings (provisional cement use), 1 restoration fracture, 1 minor chipping, 1 core fracture, 1 root fracture, and 2 implant losses. 80% of catastrophic failures occurred in patients with clinical signs of bruxism (61.7% of patients). Complications were also observed on antagonistic teeth (3 catastrophic failures). Clinical evaluation of the restorations showed good results from the aesthetic, functional, and biological perspective. Zirconia wear was inferior to 15 while glaze wear was observed on all occlusal contact areas after 1 year. Conclusions: Monolithic zirconia FPDs are promising but the failure rate of single-unit restorations was not as high as expected in this sample including patients with bruxism clinical signs. Clinical significance: Within study limitations, FPDs showed excellent short-term results but further research is needed for single-unit restorations considering samples, which do not exclude bruxers. The weak link is the restoration support or the antagonist tooth, one hypothesis being that zirconia stiffness and lack of resilience do not promote occlusal stress damping.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据