4.7 Article

Effects of simulated quarter and udder teat cup removal settings on strip milk and milking duration in dairy cows

期刊

JOURNAL OF DAIRY SCIENCE
卷 103, 期 5, 页码 4446-4454

出版社

ELSEVIER SCIENCE INC
DOI: 10.3168/jds.2019-17266

关键词

teat cup removal setting; strip milk; milking duration; milking efficiency

资金

  1. Teagasc Walsh Fellowships Programme (Teagasc Oak Park, Carlow, Ireland)
  2. University of Wisconsin-Madison

向作者/读者索取更多资源

The aim of this study was to estimate the amount of milk left in quarters and udders and the milking duration for a variety of teat cup removal strategies. A combination of empirical data and simulated quarter and udder teat cup removal settings were used to make these estimates. Milking duration is an important factor in both automatic and conventional milking systems because it directly influences milking efficiency and hence can affect farm profitability. Strategies investigated in the literature to reduce milking duration include the application of different milk flow rate switch-points (milk flow rate at which the milking unit or teat cup is removed). Applying these milk flow rate switch-points can affect the amount of milk that is not harvested (strip milk). We are not aware of previous research analyzing strip milk yield and milking duration at the quarter level, across a range of quarter and udder milk flow rate switch-points. Quarter-level average milking duration decreased by 2 min, and strip milk increased 1.3 kg as quarter milk flow rate switch-point was increased from 0.2 kg/min to 1.0 kg/min. Using an end of milking criterion of removal of the teat cup at 50% of the quarter's rolling average milk flow rate resulted in a 0.4-min reduction in milking duration and a 0.08-kg increase in strip milk per quarter, compared with removal of the teat cup at 30% of the quarter's rolling average milk flow rate. Udder-level average milking duration decreased by 1.4 min, and strip milk increased by 0.76 kg (0.19 kg per quarter) as udder milk flow rate switch-point was increased from 0.2 kg/min to 1.0 kg/min. A 0.8-min reduction in cow milking duration and a 0.27-kg increase in strip milk at the udder level (0.08 kg per quarter) resulted when changing udder milk flow rate switch-point from 30% of the udder rolling average to 50% of the udder rolling average milk flow rate. This study provides quantitative estimates of the effect of teat cup milk flow rate switch-points on milking duration and strip milk yield.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据