Technical note: Rapid field test for the quantification of vitamin E, β-carotene, and vitamin A in whole blood and plasma of dairy cattle

期刊

JOURNAL OF DAIRY SCIENCE
卷 102, 期 12, 页码 11744-11750

出版社

ELSEVIER SCIENCE INC
DOI: 10.3168/jds.2019-16755

关键词

vitamin; cow-side assay; HPLC; method comparison

向作者/读者索取更多资源

Fast and easy tests for quantifying fat-soluble vitamins such as vitamin E and vitamin A, as well as beta-carotene, in whole blood without a need to preprocess blood samples could facilitate assessment of the vitamin status of dairy cattle. The objective of this study was to validate a field-portable fluorometer/spectrophotometer assay for the rapid quantification of these vitamins in whole blood and plasma of dairy cows and calves. We measured the concentrations of vitamin E and beta-carotene in whole blood and plasma from 28 dairy cows and 11 calves using the iCheck test (Bio-Analyt GmbH, Teltow, Germany) and compared the results with the current analytical standard (HPLC) in 2 independent laboratories, one at the University of Potsdam (Germany) and at one at DSM Nutritional Products Ltd. (Kaiseraugst, Switzerland). For vitamin A, the HPLC measurements were done only in the laboratory in Germany. The whole-blood concentrations of vitamin E as determined by iCheck (blood-hematocritcorrected) ranged from 1.82 to 4.99 mg/L in dairy cows and 0.34 to 3.40 mg/L in calves. These findings were moderately correlated (R-2 = 0.66) with the values assessed by HPLC in dairy cattle (cows + calves). When calves were excluded, the correlation was higher (R-2 = 0.961). The beta-carotene and vitamin A values obtained by the reference method HPLC were highly correlated with the iCheck methods in whole blood (R-2 = 0.99 and 0.88, respectively). In plasma, we observed strong correlations between the concentrations assessed by iCheck and those of HPLC for vitamin E (R-2 = 0.97), beta-carotene (R-2 = 0.98), and vitamin A (R-2 = 0.92) in dairy cattle (cows + calves). For vitamin E, beta-carotene, and vitamin A, we compared the relationship between the differences obtained by the iCheck assay and the HPLC measurements, as well as the magnitude of measurements, using Bland-Altman plots to test for systematic bias. For all 3 vitamins, the differences values were not outside the 95% acceptability limits; we found no systematic error between the 2 methods for all 3 analytes.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据