4.5 Article

Limited view cone-beam x-ray luminescence tomography based on depth compensation and group sparsity prior

期刊

JOURNAL OF BIOMEDICAL OPTICS
卷 25, 期 1, 页码 -

出版社

SPIE-SOC PHOTO-OPTICAL INSTRUMENTATION ENGINEERS
DOI: 10.1117/1.JBO.25.1.016004

关键词

x-ray luminescence; limited view; ill-posed; depth compensation; group sparsity

资金

  1. National Key Research and Development Program of China [2017YFC0107400, 2017YFC0107401, 2017YFC0107403]
  2. National Natural Science Foundation of China [81230035]
  3. Natural Science Foundation of Shaanxi Province [2016JQ1012]
  4. Military Science and Technology Foundation [BWS14C030]

向作者/读者索取更多资源

Significance: As a promising hybrid imaging technique with x-ray excitable nanophosphors, cone-beam x-ray luminescence computed tomography (CB-XLCT) has been proposed for in-depth biological imaging applications. In situations in which the full rotation of the imaging object (or x-ray source) is inapplicable, the x-ray excitation is limited by geometry, or a lower x-ray excitation dose is mandatory, limited view CB-XLCT reconstruction would be essential. However, this will result in severe ill-posedness and poor image quality. Aim: The aim is to develop a limited view CB-XLCT imaging strategy to reduce the scanning span and a corresponding reconstruction method to achieve robust imaging performance. Approach: In this study, a group sparsity-based reconstruction method is proposed with the consideration that nanophosphors usually cluster in certain regions, such as tumors or major organs such as the liver. In addition, depth compensation (DC) is adopted to avoid the depth inconsistency caused by a limited view strategy. Results: Experiments using numerical simulations and physical phantoms with different edgeto-edge distances were carried out to illustrate the validity of the proposed method. The reconstruction results showed that the proposed method outperforms conventional methods in terms of localization accuracy, target shape, image contrast, and spatial resolution with two perpendicular projections. Conclusions: A limited view CB-XLCT imaging strategy with two perpendicular projections and a reconstruction method based on DC and group sparsity, which is essential for fast CB-XLCT imaging and for some practical imaging applications, such as imaging-guided surgery, is proposed. (C) The Authors. Published by SPIE under a Creative Commons Attribution 4.0 Unported License.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据