4.7 Article Proceedings Paper

Fuzzy self-adaptive PID control technique for driving HHO dry cell systems

期刊

INTERNATIONAL JOURNAL OF HYDROGEN ENERGY
卷 45, 期 49, 页码 26059-26069

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.ijhydene.2020.01.136

关键词

Fuzzy logic; PID; Fuzzy-PID; On/off control; Hydroxy dry cell

向作者/读者索取更多资源

When the standard operating temperatures are exceeded in hydroxy generators, production performance decreases and power consumption increases. Self-adaptive fuzzy proportional integral derivative systems have been used to prevent this situation and to maintain optimum production conditions. The Fuzzy Logic is provided to tune the optimum PID parameters by using a gain scheduling method. The tuning scheme is demonstrated by a fuzzy decision process, which consists of fuzzification, knowledge and rule base, inference and defuzzification. Results of developed fuzzy proportional integral derivative (FPID), on-off, conventional PID and fuzzy control approach are discussed and compared. The presented result shows that self-adaptive fuzzy PID controllers achieve better control performance than conventional control methods mentioned. The last but not the least, developed approach minimizes the expertise needed to apply pulse width modulation technique. (C) 2020 Hydrogen Energy Publications LLC. Published by Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据