4.3 Article

Sensitive determination of urinary muconic acid using magnetic dispersive-solid-phase extraction by magnetic amino-functionalised UiO-66

出版社

TAYLOR & FRANCIS LTD
DOI: 10.1080/03067319.2020.1727460

关键词

Metal-organic frameworks; magnetic-dispersive solid-phase extraction; sample preparation; muconic acid; urine sample

资金

  1. Hamadan University of Medical Sciences, Hamadan, Iran [9709275744]
  2. Occupational Health and Safety Research Center, Hamadan University of Medical Sciences

向作者/读者索取更多资源

In this study, a magnetic-dispersive solid-phase extraction (DSPE) method was developed for the extraction and desorption of muconic acid from real urine samples. Fe3O4-SiO2-NH2@ UiO-66 was used as a Metal-Organic Framework (MOF) in the DSPE for extraction followed by HPLC analysis. The method showed good detection limit, wide linear dynamic range, and high correlation coefficient, indicating its efficiency for the extraction and analysis of muconic acid from urine samples.
In this study, a magnetic-dispersive solid-phase extraction (DSPE) was developed for the extraction and desorption of muconic acid from real urine sample. For this purpose, Fe3O4-SiO2-NH2@ UiO-66 was used as a Metal-Organic Framework (MOF) in the DSPE for extraction of the analyte of interest followed by High-Performance Liquid Chromatography (HPLC) analysis. The synthesised magnetic-MOF was characterised by XRD, VSM, FT-IR, and FE-SEM techniques. The experimental parameters influencing the magnetic-DSPE procedure, such as solution pH, initial sample volume, extraction and desorption time, type and volume of elution solution, and sorbent amount were examined. Under the optimal conditions, the UiO-magnetic DSPE-HPLC procedure provided a good limit of detection (0.001 mu g mL(-1)), the limit of quantification (0.003 mu g mL(-1)), wide linear dynamic range (0.003-25 mu g mL(-1)) and high correlation coefficient (r(2): 0.997). Also, the Fe3O4- SiO2- NH2@ UiO-66 exhibited an acceptable accuracy (2.0-4.0%), reproducibility (3.7-6.1%), and per cent recovery (96-98%) for the extraction and desorption of the desired analyte. It can be concluded that the proposed method was efficient for the extraction and analysis of muconic acid from real urine samples. Therefore, the Fe3O4- SiO2- NH2@ UiO-66 (-) DSPE-HPLC method can be used as a simple, fast, sensitive, reusable, and user-friendly extraction technique to determine trace levels of urinary muconic acid.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据