4.6 Article

Investigation of Injection Depth for Subretinal Delivery of Exogenous Glutamate to Restore Vision via Biomimetic Chemical Neuromodulation

期刊

IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING
卷 67, 期 2, 页码 464-470

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TBME.2019.2915255

关键词

Retina; Photoreceptors; Chemicals; Neuromodulation; Rats; Synapses; Spatial resolution; Glutamate; neural prosthesis; neuromodulation; photoreceptor degeneration; retina; retinal prosthesis

资金

  1. U.S. National Science Foundation through the Emerging Frontiers in Research and Innovation Programunder [0938072]
  2. Directorate For Engineering
  3. Emerging Frontiers & Multidisciplinary Activities [0938072] Funding Source: National Science Foundation

向作者/读者索取更多资源

Chemical neuromodulation of the retina using native neurotransmitters to biomimetically activate target retinal neurons through chemical synapses is a promising biomimetic alternative to electrical stimulation for restoring vision in blindness caused by photoreceptor degenerative diseases. Recent research has shown that subretinal chemical stimulation could be advantageous for treating photoreceptor degenerative diseases but many of the parameters for achieving efficacious chemical neuromodulation are yet to be explored. In this paper, we investigated how the depth at which neurotransmitter is injected subretinally affects the success rate, spike rate characteristics (i.e., amplitude, response latency, and time width), and spatial resolution of chemical stimulation in wild-type Long Evans and photoreceptor degenerated S334ter-3 transgenic rat retinas in vitro. We compared the responses to injections of glutamate at the subretinal surface and two subsurface depths near the outer and inner plexiform layers and found that while injections at all depths elicited robust retinal ganglion cell responses, they differed significantly in terms of the spike rate characteristics and spatial resolutions across injection depths. Shallow subsurface injections near the outer plexiform layer evoked the highest spike rate amplitudes and had the highest spatial resolution and success rates, while deep subsurface injections near the inner plexiform layer elicited the shortest latencies and narrowest time widths. Our results suggest that surface injections are suboptimal for subretinal chemical neuromodulation, while shallow subsurface and deep subsurface injections may optimize high spatial and high temporal resolution, respectively. These findings have great significance for the design and development of a potential neurotransmitter-based subretinal prosthesis.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据