4.7 Editorial Material

Comments on Investigation of Histology Region Dielectric Measurements of Heterogeneous Tissues

期刊

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TAP.2019.2950078

关键词

Penetration depth; tissue dielectric properties

资金

  1. NIH/National Cancer Institute (NCI) [R01-CA191227]

向作者/读者索取更多资源

In the article, Investigation of histology region in dielectric measurements of heterogeneous tissues, by Porter and O'Halloran, the authors utilize a flexible phantom in a layered material dielectric property analysis to quantify the effective sensing volume of a coaxial dielectric probe. Ostensibly, this test has been used by others to characterize the region for which percent variation in the material composition in front of the probe corresponds to percent variation in the computed effective dielectric properties. By employing a compressible material, the authors fail to isolate features that are attributable solely to the probe, itself, and inadvertently incorporate confounding characteristics associated with the compressible nature of the material. The net effect is to exaggerate the probe's sensing volume, which undermines the conclusions drawn from the subsequent tissue dielectric property studies.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据