4.7 Article

Application of loop-mediated isothermal amplification combined with lateral flow dipstick to rapid and sensitive detection of Alexandrium catenella

期刊

ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH
卷 27, 期 4, 页码 4246-4257

出版社

SPRINGER HEIDELBERG
DOI: 10.1007/s11356-019-06889-y

关键词

Alexandrium catenella; Loop-mediated isothermal amplification; Lateral flowdipstick; Detection

资金

  1. National Scientific Foundation of China [41476086, 31600309]
  2. HIT Environment and Ecology Innovation Special Funds [HSCJ201622]
  3. HIT Scientific Research Innovation Fund/the Fundamental Research Funds for the Central Universities/the Fundamental Research Funds for the Central Universities [HIT.NSRIF.201702, HIT.NSRIF.201709]

向作者/读者索取更多资源

Alexandrium catenella is one of the globally distributed toxic marine microalgae to cause paralytic shellfish poisoning that poses a great threat to marine fisheries, economy, and public health. Development of efficient and sensitive methods for accurate identification of A. catenella to minimize its damage is therefore necessary. In this study, a novel method referred to as loop-mediated isothermal amplification (LAMP) combined with lateral flow dipstick (LFD) (LAMP-LFD) was established for rapid and sensitive detection of A. catenella. The internal transcribed spacer (ITS) gene of A. catenella was cloned for sequencing and used as target for LAMP-LFD. Three sets of LAMP primers (AcLF1, AcLF2, and AcLF3) targeting the ITS were successfully designed, among which AcLF2 displaying the best performance was used in the subsequent tests. A specific LFD probe targeting the amplification region ofAcLF2 was further designed. The LAMP-LFD detection system was established and the amplification conditions were optimized. Cross-reactivity tests with common marine microalgae showed that the LAMP-LFD was exclusively specific for A. catenella. The detection limits of LAMP-LFD for A. catenella genomic DNA and the plasmid containing the ITS were 4.63 x 10(-4) ng mu L-1 and 1.26 x 10(4) copies mu L-1, displaying a sensitivity that is 10 times higher than that of SYBR Green I assay and 100 times higher than that of conventional PCR, respectively. Finally, the practicability of LAMP-LFD was confirmed by test with spiked samples. LAMP-LFD revealed a detection limit of approximately 0.1 cell mL(-1), which was 100 times more sensitive than conventional PCR. The optimized LAMP-LFD protocol can be completed within 75 min. Therefore, the established LAMP-LFD is a specific, sensitive, and rapid method that is possibly applicable to the field monitoring of A. catenella.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据