4.6 Article

Enhancement of Neuromodulation with Novel Pulse Shapes Generated by Controllable Pulse Parameter Transcranial Magnetic Stimulation

期刊

BRAIN STIMULATION
卷 9, 期 1, 页码 39-47

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.brs.2015.08.013

关键词

Repetitive transcranial magnetic stimulation; cTMS; Inhibitory; Low frequency; Pulse shape; Latency

资金

  1. NIH [R01MH091083, 5U01MH084241, 5R01MH060884]
  2. Stanley Medical Research Institute
  3. Brain and Behavior Research Foundation
  4. Wallace H. Coulter Foundation
  5. Rogue Research for cTMS technology
  6. NATIONAL INSTITUTE OF BIOMEDICAL IMAGING AND BIOENGINEERING [R21EB006855] Funding Source: NIH RePORTER
  7. NATIONAL INSTITUTE OF MENTAL HEALTH [U01MH084241, R01MH060884, ZIAMH002955, R01MH091083] Funding Source: NIH RePORTER

向作者/读者索取更多资源

Background: Standard repetitive transcranial magnetic stimulation (rTMS) devices generate bidirectional biphasic sinusoidal pulses that are energy efficient, but may be less effective than monophasic pulses that induce a more unidirectional electric field. To enable pulse shape optimization, we developed a controllable pulse parameter TMS (cTMS) device. Objective: We quantified changes in cortical excitability produced by conventional sinusoidal bidirectional pulses and by three rectangular-shaped cTMS pulses, one bidirectional and two unidirectional (in opposite directions), and compared their efficacy in modulating motor evoked potentials (MEPs) produced by stimulation of motor cortex. Methods: Thirteen healthy subjects completed four sessions of 1 Hz rTMS of the left motor cortex. In each session, the rTMS electric field pulse had one of the four shapes. Excitability changes due to rTMS were measured by applying probe TMS pulses before and after rTMS, and comparing resultant MEP amplitudes. Separately, we measured the latency of the MEPs evoked by each of the four pulses. Results: While the three cTMS pulses generated significant mean inhibitory effects in the subject group, the conventional biphasic cosine pulses did not. The strongest inhibition resulted from a rectangular unidirectional pulse with dominant induced current in the posterior-anterior direction. The MEP latency depended significantly on the pulse shape. Conclusions: The pulse shape is an important factor in rTMS-induced neuromodulation. The standard cosine biphasic pulse showed the smallest effect on cortical excitability, while the greatest inhibition was observed for an asymmetric, unidirectional, rectangular pulse. Differences in MEP latency across the various rTMS pulse shapes suggest activation of distinct subsets of cortical microcircuitry. c 2015 Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据