4.6 Article

Specific enrichment of different Geobacter sp. in anode biofilm by varying interspatial distance of electrodes in air-cathode microbial fuel cell (MFC)

期刊

ELECTROCHIMICA ACTA
卷 331, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.electacta.2019.135388

关键词

Microbial fuel cell; Air-cathode; Pyrosequencing; Bacterial communities; Geobacter sp.; Interspatial distance

资金

  1. National Research Foundation of Korea [2015R1D1A1A09059935, 2018R1A2B2002110]
  2. Korea university grant
  3. National Research Foundation of Korea [22A20130011020] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

向作者/读者索取更多资源

Air-cathode microbial fuel cells (MFCs) were operated with variation of interspatial distance (0, 3, 6, and 9 mm), and the electrochemical performance and microbial community were comparatively evaluated. In polarization analysis the highest power densities (325 mW/m(2)) was obtained with an electrode spacing of 6 mm showing high capacitance and low charge transfer resistance. The MFC with 0 mm spacing resulted in much lower power density (53 mW/m(2)) than the other distances possibly due to high oxygen diffusion from the cathode. To compare the anode bacterial community compositions between biomass attached on the anodic electrodes, high throughput sequencing was performed. The community analyses results revealed that the three different clusters of Geobacter belonging to the Deltaproteo-bacteria were specifically enriched. The cluster I and II of Geobacter were most abundantly distributed in the 0 mm distanced sample which was exposed to relatively higher dissolved oxygen conditions while that of the cluster III was enriched in the 3, 6, and 9 mm samples. These results suggested that the cluster I and II of Geobacter species might survive better under relatively higher oxygen conditions than the cluster III Geobacter. On the other hand, relatively higher voltage and max power density were generated in the 3, 6, and 9 mm distanced MFC systems, where the cluster III Geobacter was highly enriched conditions. These results also suggested that the cluster III Geobacter might efficiently generate higher voltage and maximum power density than the other Geobacter clusters under oxygen limited conditions in air-cathode MFC system. (c) 2019 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据