4.2 Article

A Dilute-and-Shoot LC-MS/MS Method for Urinary Glyphosate and AMPA

期刊

CHROMATOGRAPHIA
卷 83, 期 3, 页码 467-475

出版社

SPRINGER HEIDELBERG
DOI: 10.1007/s10337-019-03853-3

关键词

Liquid chromatography-tandem mass spectrometry; Glyphosate; Aminomethylphosphonic acid; Method validation; Heptafluorobutyric acid

向作者/读者索取更多资源

A method for the simultaneous determination of glyphosate and aminomethylphosphonic acid (AMPA) in urine was developed using a dilute-and-shoot sample preparation. A 1:1 dilution of urine sample in 15 mmol L-1 heptafluorobutyric acid (HFBA) was prepared prior to being injected into the LC-MS/MS system. The chromatographic separation was achieved by a Gemini C6-Phenyl analytical column, with the gradient elution of 15 mmol L-1 HFBA in water and acetonitrile. The limits of detection and quantitation of both compounds were 2.5 ng mL(-1) and 5 ng mL(-1), respectively. The sample preparation time was achieved in 2 min using only 0.1 mL of urine sample. The validated method was successfully applied to glyphosate and AMPA determination in farmer urine samples. Graphic

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据