4.7 Article

Pre-cooling of air by water spray evaporation to improve thermal performance of lithium battery pack

期刊

APPLIED THERMAL ENGINEERING
卷 163, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.applthermaleng.2019.114401

关键词

Battery pack; Cooling performance; Water spray cooling; Mass flow rate; Water droplet size; Ambient temperature

资金

  1. National Natural Science Foundation of China [51776067, 51821004]
  2. National Basic Research Program of China [2015CB251503]

向作者/读者索取更多资源

The performance of battery pack is sensitive to the working temperature and often hindered by overheating, so the high efficiency cooling technology is of significant benefit to the battery performance. In this work, the air pre-cooling by water spray evaporation is applied to the battery pack thermal management. The influences of water flow rate, water droplet size, air velocity and ambient temperature on the battery performance are investigated by computational fluid dynamics. The results show that the water spray cooling can greatly reduce the maximum temperature but increase the temperature difference compared to the dry cooling. A high water flow rate leads to the reduced maximum temperature, but plays the adverse role in the maximum temperature difference. The water droplet optimal size depends on the air velocity due to its dominant roles in the residence time and diffusion behavior of droplets. When the ambient temperature is below 308.15 K and the air velocity exceeds 2 m/s, the water flow rate of 0.0002 kg/s can meet the cooling demands of battery pack.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据