4.5 Article

Improved calibration method based on the RANSAC approach and an improved gray centroid method for a laser-line-based structured light system

期刊

APPLIED OPTICS
卷 58, 期 35, 页码 9603-9613

出版社

OPTICAL SOC AMER
DOI: 10.1364/AO.58.009603

关键词

-

类别

资金

  1. National Natural Science Foundation of China [51805146]
  2. Changzhou SciTech Program [CJ20180047, CJ20190044]
  3. Fundamental Research Funds for the Central Universities [2017B07814]

向作者/读者索取更多资源

This paper proposes an improved calibration method for a structured light system by using the random sample consensus (RANSAC) method with nonlinear optimization and an improved gray centroid method. The proposed method is composed of two steps: calibrating intrinsic and extrinsic parameters for the camera, exploiting the improved gray centroid method to extract the centerline, and fitting the structured light plane by the RANSAC approach with the three-dimensional (3D) points obtained from different positions. The error function caused by the extracted centerline is deduced based on the pixel error perturbation method. The error results of the 3D points are simulated and analyzed. An imaging system is built to realize the 3D imaging. The experimental results show that the calibration error is within 0.08 mm and the reconstruction error is less than 0.45 mm. Moreover, it performs better for the reconstruction of complex objects compared with traditional methods. (C) 2019 Optical Society of America

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据