4.8 Article

Influencing sensitivities of critical operating parameters on PEMFC output performance and gas distribution quality under different electrical load conditions

期刊

APPLIED ENERGY
卷 255, 期 -, 页码 -

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.apenergy.2019.113849

关键词

Proton exchange membrane fuel cell; Influencing sensitivity; Gas distribution; Output performance; Critical operating parameters

资金

  1. Shanghai Sailing Program [18YF1424300]
  2. National Natural Science Foundation of China [21805210]
  3. Ministry of Science and Technology of China [2018YFB0105405, 2017YFB0103102]
  4. Fundamental Research Funds for the Central Universities [1700219153]

向作者/读者索取更多资源

Proton exchange membrane fuel cell has certain requirements on operating conditions. Suitable operating parameters can not only improve the output performance, but also prolong the life duration of fuel cells. Existing studies on the effects of operating parameters on fuel cell performance are often qualitative and lack quantitative indicator of influencing sensitivity. Moreover, there is currently almost no research on impacts of operating parameters on fuel cell internal reactant gas distribution, but local gas starvation caused by uneven gas distribution is one of the crucial reasons for fuel cell lifetime degradation. In this paper, a three-dimensional model of a three-channel serpentine flow field fuel cell is established to study the impacts of seven critical operating parameters on fuel cell output performance and internal gas concentration distribution under different load conditions. By calculating the influential proportion of each operating parameter, its influencing sensitivity on fuel cell performance is quantitatively evaluated. The changing trends of each operating parameter's impact and influencing sensitivity on the output voltage, the mean value and standard deviation of internal gas molar concentration distribution under different load conditions are also analyzed. Besides, the optimal operating parameters combinations at various loads have been summarized based on simulation and calculation results. The research content of this paper can make up for the current vacancy research on impacts of operating parameters on fuel cell internal gas distribution, the quantitative evaluation method of influential sensitivity proposed in this paper can be reference for the operational parameters studies, and the conclusions of this paper can provide more specific guidance for fuel cell performance improvement and control optimization.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据