4.8 Article

DNAzyme-Triggered Visual and Ratiometric Electrochemiluminescence Dual-Readout Assay for Pb(II) Based on an Assembled Paper Device

期刊

ANALYTICAL CHEMISTRY
卷 92, 期 5, 页码 3874-3881

出版社

AMER CHEMICAL SOC
DOI: 10.1021/acs.analchem.9b05343

关键词

-

资金

  1. National Natural Science Foundation of China [21904047]
  2. Shandong Provincial Natural Science Foundation [ZR2018PD004, ZR201709250117]
  3. National Postdoctoral Program for Innovative Talents of China [BX20180129]
  4. Key Research and Development Program of Shandong Province [2019GGX104055]
  5. Taishan Scholars Program, Case-by-Case Project for Top Outstanding Talents of Jinan
  6. project of 20 items of University of Jinan [2018GXRC001]

向作者/读者索取更多资源

Currently, portable, low-cost, and easy to operate on-chip analytical units are urgently demanded to meet the requirement for point-of-care testing in resource-limited regions. Herein, a dual-mode lab-on-paper platform is presented, which integrates distance-based visualized readout with ratiometric electrochemiluminescence (ECL) assay in one device. The distance-based measurement is based on a brown visualized strip generated from the oxidation reaction of 3,3'-diaminobenzidine in the presence of H2O2 initiated by horseradish peroxidase (HRP). Notably, visualized semiquantitative results are displayed as the length of a brown bar chart directly on the device-without the need for any data processing or plotting steps, thus avoiding the error caused by the naked eye for distinguishing the color depth. On the contrary, a ratiometric ECL technique was employed for accurate analysis based on the specific biorecognition between Pb2+-dependent DNAzymes and targets. Concretely, upon addition of Pb2+ into the fabricated device, cleaved oligonucleotide fragments connected with HRP functionalized Au nanocubes could permeate through the cellulose on account of their size that is smaller than paper pores, quench the ECL signal of the CdS quantum dots because of resonance energy transfer, and synchronously boost the ECL intensity generated from luminol by catalyzing H2O2. As a consequence, satisfied prediction and accurate monitoring performance was obtained in the range 0.1-2000 nM and 0.01-2000 nM by measuring the length of colored product and the ratio of ECL intensity, respectively. The beneficial advantages of low cost, high efficiency, and the capacity to perform dual-mode assay qualify this innovative device for use with diverse applications.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据