4.7 Article

Systematic assessment of extraction of pharmaceuticals and personal care products in water and sediment followed by liquid chromatography-tandem mass spectrometry

期刊

ANALYTICAL AND BIOANALYTICAL CHEMISTRY
卷 412, 期 1, 页码 113-127

出版社

SPRINGER HEIDELBERG
DOI: 10.1007/s00216-019-02207-0

关键词

Pharmaceuticals and personal care products; Ion pairing; Environmental matrices; High-performance liquid chromatography-tandem and mass spectrometry; Sodium dodecyl sulfate solution; Solid-phase extraction

资金

  1. Spanish Ministry of Science, Innovation and Universities through the project WETANDPAC [RTI2018-097158-B-C31]
  2. European Regional Development Fund through the project WETANDPAC [RTI2018-097158-B-C31]
  3. Generalitat Valenciana through the project ANTROPOCEN@ [PROMETEO/2018/155]
  4. Generalitat Valenciana [GRISOLIAP/2018/102, CPI-18-118]

向作者/读者索取更多资源

Two solid-phase extraction methods were systematically studied to determine 32 pharmaceuticals and personal care products in water and sediments by ultrahigh-performance liquid chromatography-tandem mass spectrometry. One involves HLB cartridges activated with sodium dodecyl sulfate before the passage of the sample to form an ion pair with cationic analytes, and the other uses mixed HLB-cation exchange cartridges. The accuracy of the sodium dodecyl sulfate method was good for most compounds (recoveries of 61-120% with relative standard deviation less than 23%). However, the recoveries for atorvastatin, codeine, paracetamol, flufenamic acid, and salicylic acid were approximately 50% and for omeprazole and triclocarban were even lower (from 0 to 12%). The detection limits were 1.65-25 ng L-1 in water and 0.33-4.00 ng g(-1) (dry weight) in sediment. The recoveries for the mixed-mode cartridge (Strata-X-CW) method ranged from 57% to 120% with relative standard deviation less than 21%, with the exception of codeine [25% (water)], metformin [11% (sediment)], paracetamol [48% (sediment)], and salicylic acid [32% (sediment)]. The detection limits were 1.65-38.35 ng L-1 in water and 0.33-10 ng g(-1) (dry weight) in sediment. Both methods followed the same pattern when applied to water. For sediments, the recoveries, which offer good performance, were not very high, although 60% of the compounds had recoveries greater 80%. The methods were applied to the analysis of surface water and sediments from the Albufera Natural Park (Spain). Twenty-seven of 32 analytes were detected in the samples analyzed.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据