3.8 Article

Mitigation of Peri-implantitis by Rational Design of Bifunctional Peptides with Antimicrobial Properties

期刊

ACS BIOMATERIALS SCIENCE & ENGINEERING
卷 6, 期 5, 页码 2682-2695

出版社

AMER CHEMICAL SOC
DOI: 10.1021/acsbiomaterials.9b01213

关键词

peri-implant disease; bifunctional peptides; antimicrobial; structure; function; titanium/Ti alloy implant; dental implant; stability; peptide film

资金

  1. National Institute of Arthritis and Musculoskeletal and Skin Diseases (NIAMS) [R21 AR062249]
  2. National Institute of Dental and Craniofacial Research (NIDCR) of the National Institutes of Health [R43 DE027306]

向作者/读者索取更多资源

The integration of molecular and cell biology with materials science has led to strategies to improve the interface between dental implants with the surrounding soft and hard tissues to replace missing teeth and restore mastication. More than 3 million implants have been placed in the US alone, and this number is rising by 500 000 per year. Peri-implantitis, an inflammatory response to oral pathogens growing on the implant surface, threatens to reduce service life leading to eventual implant failure, and such an outcome will have an adverse impact on public health and create significant health care costs. Here, we report a predictive approach to peptide design, which enabled us to engineer a bifunctional peptide to combat bacterial colonization and biofilm formation, reducing the adverse host inflammatory immune response that destroys the tissue surrounding implants and shortens their life spans. This bifunctional peptide contains a titanium-binding domain that recognizes and binds with high affinity to titanium implant surfaces, fused through a rigid spacer domain with an antimicrobial domain. By varying the antimicrobial peptide domain, we were able to predict the properties of the resulting bifunctional peptides in their entirety by analyzing the sequence-structure-function relationship. These bifunctional peptides achieve (1) nearly 100% surface coverage within minutes, a time frame suitable for their clinical application to existing implants, (2) nearly 100% binding to a titanium surface even in the presence of contaminating serum protein, (3) durability to brushing with a commercially available electric toothbrush, and (4) retention of antimicrobial activity on the implant surface following bacterial challenge. A bifunctional peptide film can be applied to both new implants or repeatedly applied to previously placed implants to control bacterial colonization mitigating peri-implant disease that threatens dental implant longevity.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

3.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据