4.5 Article

Respiratory variations of inferior vena cava fail to predict fluid responsiveness in mechanically ventilated patients with isolated left ventricular dysfunction

期刊

ANNALS OF INTENSIVE CARE
卷 9, 期 1, 页码 -

出版社

SPRINGER
DOI: 10.1186/s13613-019-0589-5

关键词

Echocardiography; Inferior vena cava; Fluid responsiveness; Heart function; Critically ill

向作者/读者索取更多资源

Background Respiratory variation of inferior vena cava is problematic in predicting fluid responsiveness in patients with right ventricular dysfunction. However, its effectiveness in patients with isolated left ventricular systolic dysfunction (ILVD) has not been reported. We aimed to explore whether inferior vena cava diameter distensibility index (dIVC) can predict fluid responsiveness in mechanically ventilated ILVD patients. Methods Patients admitted to the intensive care unit who were on controlled mechanical ventilation and in need of a fluid responsiveness assessment were screened for enrolment. Several echocardiographic parameters, including dIVC, tricuspid annular plane systolic excursion (TAPSE), left ventricular ejection fraction (LVEF), and LV outflow tract velocity-time integral (VTI) before and after passive leg raising (PLR) were collected. Patients with LV systolic dysfunction only (TAPSE >= 16 mm, LVEF < 50%) were considered to have isolated left ventricular systolic dysfunction (ILVD). Results One hundred and twenty-nine subjects were enrolled in this study, among them, 28 were labelled ILVD patients, and the remaining 101 were patients with normal LV function (NLVF). The value of dIVC in ILVD patients was as high as that in NLVF patients, (20% vs. 16%, p = 0.211). The ILVD group contained a much lower proportion of PLR responders than NLVF patients did (17.9% vs. 53.2%, p < 0.001). No correlation was detected between dIVC and Delta VTI in ILVD patients (r = 0.196, p = 0.309). dIVC was correlated with Delta VTI in NLVF patients (r = 0.722, p < 0.001), and the correlation was strengthened compared with that derived from all patients (p = 0.020). A receiver-operating characteristic (ROC) analysis showed that the area-under-the-curve (AUC) of dIVC for determining fluid responsiveness from ILVD patients was not statistically significant (p = 0.251). In NLVF patients, ROC analysis revealed an AUC of 0.918 (95% CI 0.858-0.978; p < 0.001), which was higher than the AUC derived from all patients (p = 0.033). Patients with LVEF below 40% had a lower Delta VTI and fewer PLR responders than those with LVEF 40-50% and LVEF above 50% (p < 0.001). Conclusion dIVC should be used with caution when critically ill patients on controlled mechanical ventilation display normal right ventricular function in combination with abnormal left ventricular systolic function.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据