4.4 Article

Numerical investigation of the wind environment around tall buildings in a central business district

期刊

FRONTIERS OF EARTH SCIENCE
卷 13, 期 4, 页码 848-858

出版社

SPRINGER
DOI: 10.1007/s11707-019-0787-3

关键词

wind environment; pedestrian-level wind; computational fluid dynamics; wind speed ratio; central business district

资金

  1. Ministry of Science and Technology of the People's Republic of China [2015CB452806, 2018YFB1501104]
  2. National Natural Science Foundation of China [51408196]
  3. Natural Science Foundation of Shanghai [19ZR1469200]
  4. State Key Laboratory for Disaster Reduction in Civil Engineering [SLDRCE15-A-04]
  5. Study on the Wind Characteristics Caused by Typhoons Considering Offshore Wind Farm Safety along Fujian Province [2016FD(8)-008]

向作者/读者索取更多资源

The wind environment around tall buildings in a central business district (CBD) was numerically investigated. The district covers an area of similar to 4.0 km(2) and features a high density of tall buildings. In this study, only buildings taller than 20 m were considered, resulting in 173 tall buildings in the analysis. The numerical investigation was realized using the commercial computational fluid dynamics code FLUENT with the realizable k - epsilon turbulence model. Special efforts were made to maintain inflow boundary conditions throughout the computational domain. The reliability of the numerical method was validated using results from an experimental investigation conducted in the core area of the CBD (similar to 1.5 km(2)). Experimental and numerical investigations of wind speed ratios at the center of the three tallest buildings in the CBD agree within an uncertainty factor of 2.0. Both the experimental and numerical results show that wind speed ratios in the wind field with exposure category D are higher than those from the wind field with exposure category B. Based on the above validation work, the wind environment around tall buildings in the whole CBD was then investigated by numerical simulation. Common flow phenomena and patterns, such as stagnation points, shielding effects, separation flow, and channeling flow, were identified around the tall buildings. The pedestrianlevel wind environment around tall buildings in the CBD was further evaluated using nearby meteorological wind data. The evaluation results show that some pedestrian activities, such as sitting at the center of the three tallest buildings, are unadvisable when the wind blows from the south-east.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据