4.7 Article

Ultrasonically assisted synthesis of barium stannate incorporated graphitic carbon nitride nanocomposite and its analytical performance in electrochemical sensing of 4-nitrophenol

期刊

ULTRASONICS SONOCHEMISTRY
卷 62, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.ultsonch.2019.104855

关键词

Graphitic carbon nitride; Barium stannate; 4-Nitrophenol; Cyclic voltammetry; Linear sweep voltammetry; Electrochemical sensors

资金

  1. DST-SERB, New Delhi through Early Career Research Award (ECRA) (SERB) [ECR/2017/001758]
  2. DST-Inspire fellowship under AORC scheme [IF170687]

向作者/读者索取更多资源

We describe the ultrasonic assisted preparation of barium stannate-graphitic carbon nitride nanocomposite (BSO-gCN) by a simple method and its application in electrochemical detection of 4-nitrophenol via electrooxidation. A bath type ultrasonic cleaner with ultrasonic power and ultrasonic frequency of 100 W and 50 Hz, respectively, was used for the synthesis of BSO-gCN nanocomposite material. The prepared BSO-gCN nanocomposite was characterized by employing several spectroscopic and microscopic techniques such as X-ray diffraction, X-ray photoelectron spectroscopy, fourier transform infra-red, field emission scanning electron microscopy, and high resolution transmission electron microscopy, to unravel the structural and electronic features of the prepared nanocomposite. The BSO-gCN was drop-tasted on a pre-treated glassy carbon electrode (GCE), and their sensor electrode was utilized for electrochemical sensing of 4-nitrophenol (4-NP). The BSO-gCN modified GCE exhibited better electrochemical sensing behavior than the bare GCE and other investigated electrodes. The electroanalytical parameters such as charge transfer coefficient (alpha = 0.5), the rate constant for electron transfer (k(s) = 1.16 s(-1)) and number of electron transferred were calculated. Linear sweep voltammetry (LSV) exhibited increase in peak current linearly with 4-NP concentration in the range between 1.6 and 50 mu M. The lowest detection limit (LoD) was calculated to be 1 mu M and sensitivity of 0.81 mu A mu M-1 cm(-2) A 100-fold excess of various ions, such as Ca2+, Na+, K+, Cl-, I-, CO32-, NO3, NH4+ and SO42- did not able to interfere with the determination of 4-NP and high sensitivity for detecting 4-NP in real samples was achieved. This newly developed BSO-gCN could be a potential candidate for electrochemical sensor applications.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据