4.8 Article

Direct quantification of transendothelial electrical resistance in organs on-chips

期刊

BIOSENSORS & BIOELECTRONICS
卷 85, 期 -, 页码 924-929

出版社

ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/j.bios.2016.06.014

关键词

Transendothelial electrical resistance; Transepithelial electrical resistance; Organs-on-chips; Blood-brain barrier on chip; Microfluidics

资金

  1. SRO Biomedical Microdevices, MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente, the Netherlands
  2. SRO Organs-on-chips, MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente, the Netherlands
  3. VESCEL, ERC Advanced Grant [669768]

向作者/读者索取更多资源

Measuring transendothelial or transepithelial electrical resistance (TEER) is a widely used method to monitor cellular barrier tightness in organs-on-chips. Unfortunately, integrated electrodes close to the cellular barrier hamper visual inspection of the cells or require specialized cleanroom processes to fabricate see-through electrodes. Out-of-view electrodes inserted into the chip's outlets are influenced by the fluid-filled microchannels with relatively high resistance. In this case, small changes in temperature or medium composition strongly affect the apparent TEER. To solve this, we propose a simple and universally applicable method to directly determine the TEER in microfluidic organs-on-chips without the need for integrated electrodes close to the cellular barrier. Using four electrodes inserted into two channels two on each side of the porous membrane and six different measurement configurations we can directly derive the isolated TEER independent of channel properties. We show that this method removes large variation of non-biological origin in chips filled with culture medium. Furthermore, we demonstrate the use of our method by quantifying the TEER of a monolayer of human hCMEC/D3 cerebral endothelial cells, mimicking the blood-brain barrier inside our microfluidic organ-on-chip device. We found stable TEER values of 22 Omega cm(2) +/- 1.3 Omega cm(2) (average +/- standard error of the mean of 4 chips), comparable to other TEER values reported for hCMEC/D3 cells in well-established Transwell systems. In conclusion, we demonstrate a simple and robust way to directly determine TEER that is applicable to any organ-on-chip device with two channels separated by a membrane. This enables stable and easily applicable TEER measurements without the need for specialized cleanroom processes and with visibility on the measured cell layer. (C) 2016 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据