4.7 Article

Continuous-flow aerobic granulation in plug-flow bioreactors fed with real domestic wastewater

期刊

SCIENCE OF THE TOTAL ENVIRONMENT
卷 688, 期 -, 页码 762-770

出版社

ELSEVIER
DOI: 10.1016/j.scitotenv.2019.06.291

关键词

Aerobic granule; Plug flow reactor; Sequential batch rector; Completely stirred tank reactor; Selection pressure; Settleability

向作者/读者索取更多资源

This pilot study was designed to explore the feasibility of achieving successful aerobic granulation in continuous flow infrastructure like that existing in modern wastewater treatment plants (WWTPs). Results demonstrated that aerobic granulation of activated sludge can be achieved in plug-flow reactors (PFRs) fed with primary effluent from a domestic WWTP with seasonal temperature variation between 10 and 22.5 degrees C. It took about 90 days during the reactor startup to reach a state of sustained aerobic granulation. The characteristics of aerobic granules formed were comparable to those measured in sequential batch reactors (SBRs). The feast-to-famine concentration profiles measured in the plug-flow pilot reactors were found to be in line with those present in the full-scale treatment trains, lending support to the feasibility of converting existing infrastructure to continuous flow aerobic granulation systems. A selection pressure based on settling velocity (V-s) was applied in a V-s selector to retain bioparticles with V-s greater than similar to 9-9.75 m h(-1). It was theorized that an external V-s selection pressure would be necessary but would not be the sole condition sufficient to drive aerobic granulation. The alternating feast-tofamine internal selection provided by the PFRs is also believed to be a required condition to transform biomass from flocs toward dense and compact aerobic granules. While the pilot-scale Plug-flow Aerobic Granulation (PAG) reactor achieved similar COD and NH3 removal efficiencies as the full-scale WWTP treatment train, its effluent from V, selector contained an average of 138 mg L-1 total suspended solids (TSS) as a result of the biomass 'wash-out by the V-s selection pressure. Pilot results suggest a second clarifier for polishing, in addition to the V-s selector, may be needed in a full-scale application of the technique unless other downstream processes (flocculation, sedimentation, filtration) are provided to reach final water quality goals. Published by Elsevier B.V.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据