4.7 Article

Efficient removal of parabens from real water matrices by a metal-free carbon nitride photocatalyst

期刊

SCIENCE OF THE TOTAL ENVIRONMENT
卷 716, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.scitotenv.2019.135346

关键词

Photocatalysis; Degradation; Parabens; Carbon nitride; Visible light; Water matrices

资金

  1. European Regional Development Fund (ERDF) through COMPETE2020 - Programa Operacional Competitividade e Internacionalizacao (POCI) [POCI-01-0145-FEDER-030674, POCI-01-0145-FEDER-031398, POCI-01-0145-FEDER-029600]
  2. FCT - Fundacao para a Ciencia e a Tecnologia I.P.
  3. Norte Portugal Regional Operational Programme (NORTE 2020) under the PORTUGAL 2020 Partnership Agreement, through the European Social Fund (ESF) [NORTE-08-5369-FSE000028]
  4. FCT Investigator Programme [IF/00514/2014]
  5. European Social Fund
  6. Human Potential Operational Programme
  7. Associate Laboratory LSRE-LCM (Laboratory of Separation and Reaction Engineering - Laboratory of Catalysis and Materials), Portugal [POCI-01-0145-FEDER-006984]

向作者/读者索取更多资源

Metal-free graphite-like carbon nitride (GCN-500) was obtained by thermal post-treatment of bulk polymeric carbon nitride at 500 degrees C. The catalyst was thoroughly characterized by morphological, optical and textural analysis techniques. The efficiency of GCN-500 was evaluated under visible (lambda(exc) = 417 nm) LED excitation for the photocatalytic degradation of methyl-, ethyl- and propyl-paraben in different water matrices either isolated or in a mixture of the three compounds. The GCN-500 proved to be more efficient than the benchmark TiO2 P25, with complete conversion of the individual parabens within 20 min of irradiation, contrasting with 120 min needed for total degradation using TiO2. Experiments in the presence of selected scavengers confirmed the high importance of superoxide radicals in the photocatalytic oxidation of parabens using GCN-500. The effect of the nature of the aqueous matrix in the kinetics of the photocatalytic process was assessed using ultrapure, tap and river waters spiked with a mixture of the three parabens. Although still very efficient, the complexity of the real water samples turned the degradation process slower due to the presence of other components such as ions and dissolved organic matter. GCN-500 proved to be stable in a continuous-flow system using GCN-500 coated glass rings (GCN-500-GR) to remove MP, EP and PP from real water matrices. (C) 2019 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据