4.7 Article

Acute Effects of Electronic Cigarette Aerosol Inhalation on Vascular Function Detected at Quantitative MRI

期刊

RADIOLOGY
卷 293, 期 1, 页码 97-106

出版社

RADIOLOGICAL SOC NORTH AMERICA
DOI: 10.1148/radiol.2019190562

关键词

-

资金

  1. National Institutes of Health [R01 HL109545, R01 HL139358]
  2. National Heart, Lung, and Blood Institute [R01 HL109545, R01 HL139358]

向作者/读者索取更多资源

Background: Previous studies showed that nicotinized electronic cigarettes (hereafter, e-cigarettes) elicit systemic oxidative stress and inflammation. However, the effect of the aerosol alone on endothelial function is not fully understood. Purpose: To quantify surrogate markers of endothelial function in nonsmokers after inhalation of aerosol from nicotine-free e-cigarettes. Materials and Methods: In this prospective study (from May to September 2018), nonsmokers underwent 3.0-T MRI before and after inhaling nicotine-free e-cigarette aerosol. Peripheral vascular reactivity to cuff-induced ischemia was quantified by temporally resolving blood flow velocity and oxygenation (SvO(2)) in superficial femoral artery and vein, respectively, along with artery luminal flow-mediated dilation. Precuff occlusion, resistivity index, baseline blood flow velocity, and SvO(2) were evaluated. During reactive hyperemia, blood flow velocity yielded peak velocity, time to peak, and acceleration rate (hyperemic index); SvO(2) yielded washout time of oxygen-depleted blood, rate of resaturation, and maximum SvO(2) increase (overshoot). Cerebrovascular reactivity was assessed in the superior sagittal sinus, evaluating the breath-hold index. Central arterial stiffness was measured via aortic pulse wave velocity. Differences before versus after e-cigarette vaping were tested with Hotelling T-2 test. Results: Thirty-one healthy never-smokers (mean age, 24.3 years +/- 4.3; 14 women) were evaluated. After e-cigarette vaping, resistivity index was higher (0.03 of 1.30 [2.3%]; P < .05), luminal flow-mediated dilation severely blunted (-3.2% of 9.4% [-34%]; P < .001), along with reduced peak velocity (-9.9 of 56.6 cm/sec [-17.5%]; P < .001), hyperemic index (-3.9 of 15.1 cm/sec(2) [-25.8%]; P < .001), and delayed time to peak (2.1 of 7.1 sec [29.6%]; P = .005); baseline SvO(2) was lower (-13 of 65 %HbO(2) [-20%]; P < .001) and overshoot higher (10 of 19 %HbO(2) [ 52.6%]; P < .001); and aortic pulse wave velocity marginally increased (0.19 of 6.05 m/sec [3%]; P = .05). Remaining parameters did not change after aerosol inhalation. Conclusion: Inhaling nicotine-free electronic cigarette aerosol transiently impacted endothelial function in healthy nonsmokers. Further studies are needed to address the potentially adverse long-term effects on vascular health. (C) RSNA, 2019

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据