4.6 Article

A multi-scale framework with unsupervised joint training of convolutional neural networks for pulmonary deformable image registration

期刊

PHYSICS IN MEDICINE AND BIOLOGY
卷 65, 期 1, 页码 -

出版社

IOP Publishing Ltd
DOI: 10.1088/1361-6560/ab5da0

关键词

deformable image registration; multi-scale framework; joint training; convolutional neural network; unsupervised learning

资金

  1. National Institutes of Health [R01-CA184173, R01-EB028324]
  2. Chinese Scholarship Council (CSC)

向作者/读者索取更多资源

To achieve accurate and fast deformable image registration (DIR) for pulmonary CT, we proposed a Multi-scale DIR framework with unsupervised Joint training of Convolutional Neural Network (MJ-CNN). MJ-CNN contains three models at multi-scale levels for a coarse-to-fine DIR to avoid being trapped in a local minimum. It is trained based on image similarity and deformation vector field (DVF) smoothness, requiring no supervision of ground-truth DVF. The three models are first trained sequentially and separately for their own registration tasks, and then are trained jointly for an end-to-end optimization under the multi-scale framework. In this study, MJ-CNN was trained using public SPARE 4D-CT data. The trained MJ-CNN was then evaluated on public DIR-LAB 4D-CT dataset as well as clinical CT-to-CBCT and CBCT-to-CBCT registration. For 4D-CT inter-phase registration, MJ-CNN achieved comparable accuracy to conventional iteration optimization-based methods, and showed the smallest registration errors compared to recently published deep learning-based DIR methods, demonstrating the efficacy of the proposed multi-scale joint training scheme. Besides, MJ-CNN trained using one dataset (SPARE) could generalize to a different dataset (DIR-LAB) acquired by different scanners and imaging protocols. Furthermore, MJ-CNN trained on 4D-CTs also performed well on CT-to-CBCT and CBCT-to-CBCT registration without any re-training or fine-tuning, demonstrating MJ-CNN's robustness against applications and imaging techniques. MJ-CNN took about 1.4 s for DVF estimation and required no manual-tuning of parameters during the evaluation. MJ-CNN is able to perform accurate DIR for pulmonary CT with nearly real-time speed, making it very applicable for clinical tasks.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据