Technical Note: Film-based measurement of gold nanoparticle dose enhancement for 192Ir

期刊

MEDICAL PHYSICS
卷 47, 期 1, 页码 260-266

出版社

WILEY
DOI: 10.1002/mp.13884

关键词

Burlin cavity theory; dose enhancement; gold nanoparticles

资金

  1. San Antonio Medical Foundation
  2. National Institute on Minority Health and Health Disparities from the National Institutes of Health [G12MD007591]
  3. UTSA Kleberg Advanced Microscopy Center

向作者/读者索取更多资源

Purpose The purpose of this work is to introduce a simple yet accurate technique to measure the dose enhancement factor (DEF) of a citrate-capped gold nanoparticle (GNP) solution using EBT3 film in an Ir-192 setup. Methods Dose enhancement factor is the ratio of absorbed dose in a solution compared to absorbed dose in water, assuming identical irradiation parameters. Citrate-capped GNPs were synthesized. An acrylic apparatus was constructed such that the EBT3 film was placed in charged particle equilibrium within the GNP solution with 0.28%, 0.56%, and 0.77% gold by mass. Sets of 12 dose measurements were collected for each GNP concentration as well as for water. The expected value of DEF was also calculated with the effective mass absorption coefficient of the GNP solution and water for an Ir-192 spectrum. Furthermore, Burlin cavity correction factors were calculated and experimentally verified. Experimental verification of the cavity correction was performed by measuring DEF using stacks of 1, 3, and 5 sheets of film and extrapolating the DEF to 0 sheets of film. Results Experimental cavity corrections agreed with those calculated with the Burlin cavity formalism. The calculated DEF was 1.013, 1.027, and 1.037 for the 0.28%, 0.56%, and 0.77% gold by mass GNP solutions, respectively. The corresponding uncorrected DEF measurement values were 1.013 +/- 0.006, 1.024 +/- 0.010, and 1.032 +/- 0.006, respectively. When applying the Burlin cavity formalism, the final corrected DEF measurement values were 1.016 +/- 0.006, 1.029 +/- 0.010, and 1.039 +/- 0.006, respectively. Conclusion The experimental cavity correction results agreed with the theoretical Burlin calculations, which allowed for the Burlin corrections to be performed for all GNP concentrations and measured DEF values. The adjusted DEF values agreed with the theoretical calculations. Thus, these results indicate that a Burlin cavity calculation can be applied to correct film-based DEF measurements for Ir-192.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据