4.5 Article

Calibration of arterial spin labeling data-potential pitfalls in post-processing

期刊

MAGNETIC RESONANCE IN MEDICINE
卷 83, 期 4, 页码 1222-1234

出版社

WILEY
DOI: 10.1002/mrm.28000

关键词

ASL; calibration; cerebral blood flow; kinetic modeling; MRI

资金

  1. Portuguese Foundation for Science and Technology (FCT) [PTDC/BBB-IMG/2137/2012, PD/BD/135114/2017]
  2. Engineering and Physical Sciences Research Council UK [EP/P012361/1]
  3. Wellcome Trust [203139/Z/16/Z.]
  4. Fundação para a Ciência e a Tecnologia [PD/BD/135114/2017] Funding Source: FCT
  5. EPSRC [EP/P012361/2, EP/P012361/1] Funding Source: UKRI

向作者/读者索取更多资源

Purpose: To assess the impact of the different post-processing options in the calibration of arterial spin labeling (ASL) data on perfusion quantification and its reproducibility. Theory and Methods: Absolute quantification of perfusion measurements is one of the promises of ASL techniques. However, it is highly dependent on a calibration procedure that involves a complex processing pipeline for which no standardized procedure has been fully established. In this work, we systematically compare the main ASL calibration methods as well as various post-processing calibration options, using 2 data sets acquired with the most common sequences, pulsed ASL and pseudo-continuous ASL. Results: Significant and sometimes large discrepancies in ASL perfusion quantification were obtained when using different post-processing calibration options. Nevertheless, when using a set of theoretically based and carefully chosen options, only small differences were observed for both reference tissue and voxelwise methods. The voxelwise and white matter reference tissue methods were less sensitive to post-processing options than the cerebrospinal fluid reference tissue method. However, white matter reference tissue calibration also produced poorer reproducibility results. Moreover, it may also not be an appropriate reference in case of white matter pathology. Conclusion: Poor post-processing calibration options can lead to large errors in perfusion quantification, and a complete description of the calibration procedure should therefore be reported in ASL studies. Overall, our results further support the voxelwise calibration method proposed by the ASL white paper, particularly given the advantage of being relatively simple to implement and intrinsically correcting for the coil sensitivity profile.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据