4.2 Article

Dense and dangerous: The tissue plasminogen activator-resistant fibrinolysis shutdown phenotype is due to abnormal fibrin polymerization

期刊

JOURNAL OF TRAUMA AND ACUTE CARE SURGERY
卷 88, 期 2, 页码 258-265

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/TA.0000000000002554

关键词

Trauma; coagulopathy; fibrin; fibrinolysis; tissue plasminogen activator; thrombelastography

资金

  1. National Institutes of Health [UM1HL120877, R01GM123010, R35HL140027, T32GM08315]

向作者/读者索取更多资源

BACKGROUND Both hyperfibrinolysis and fibrinolysis shutdown can occur after severe trauma. The subgroup of trauma patients with fibrinolysis shutdown resistant to tissue plasminogen activator (t-PA)-mediated fibrinolysis have increased mortality. Fibrin polymerization and structure may influence fibrinolysis subgroups in trauma, but fibrin architecture has not been characterized in acutely injured subjects. We hypothesized that fibrin polymerization measured in situ will correlate with fibrinolysis subgroups. METHODS Blood samples were collected from trauma patients and noninjured controls. We selected samples across a range of fibrinolysis phenotypes (shutdown, physiologic, hyperfibrinolysis) and t-PA sensitivities (sensitive, physiologic, resistant) determined by thrombelastography. Plasma clots were created in situ with fluorescent fibrinogen and imaged using confocal microscopy for analysis of clot architecture in three dimensions. For each clot, we quantified the fiber resolvability, a metric of fiber distinctness or clarity, by mapping the variance of fluorescence intensity relative to background fluorescence. We also determined clot porosity by measuring the size and distribution of the gaps between fibrin fibers in three-dimensional space. We compared these measures across fibrinolysis subgroups. RESULTS Fiber resolvability was significantly lower in all trauma subgroups compared with controls (n = 35 and 5, respectively; p < 0.05). We observed markedly different patterns of fibrin architecture among trauma patients stratified by fibrinolysis subgroup. Subjects with t-PA-resistant fibrinolysis shutdown exhibited abnormal, densely packed fibrin clots nearly devoid of pores. Individuals with t-PA-hypersensitive fibrinolysis shutdown had highly irregular clots with pores as large as 2500 mu m(3) to 20,000 mu m(3), versus 78 mu m(3) to 1250 mu m(3) in noninjured controls. CONCLUSION Fiber resolvability was significantly lower in trauma patients than controls, and subgroups of fibrinolysis differ in the porosity of the fibrin clot structure. The dense fibrin network in the t-PA-resistant group may prevent access to plasmin, suggesting a mechanism for thrombotic morbidity after injury.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据