Consumer activity trackers claiming to measure sleep/wake patterns are ubiquitous within clinical and consumer settings. However, validation of these devices in sleep disorder populations are lacking. We examined 1 night of sleep in 42 individuals with insomnia (mean = 49.14 +/- 17.54 years) using polysomnography, a wrist actigraph (Actiwatch Spectrum Pro: AWS) and a consumer activity tracker (Fitbit Alta HR: FBA). Epoch-by-epoch analysis and Bland-Altman methods evaluated each device against polysomnography for sleep/wake detection, total sleep time, sleep efficiency, wake after sleep onset and sleep latency. FBA sleep stage classification of light sleep (N1 + N2), deep sleep (N3) and rapid eye movement was also compared with polysomnography. Compared with polysomnography, both activity trackers displayed high accuracy (81.12% versus 82.80%, AWS and FBA respectively; ns) and sensitivity (sleep detection; 96.66% versus 96.04%, respectively; ns) but low specificity (wake detection; 39.09% versus 44.76%, respectively; p = .037). Both trackers overestimated total sleep time and sleep efficiency, and underestimated sleep latency and wake after sleep onset. FBA demonstrated sleep stage sensitivity and specificity, respectively, of 79.39% and 58.77% (light), 49.04% and 95.54% (deep), 65.97% and 91.53% (rapid eye movement). Both devices were more accurate in detecting sleep than wake, with equivalent sensitivity, but statistically different specificity. FBA provided equivalent estimates as AWS for all traditional actigraphy sleep parameters. FBA also showed high specificity when identifying N3, and rapid eye movement, though sensitivity was modest. Thus, it underestimates these sleep stages and overestimates light sleep, demonstrating more shallow sleep than actually obtained. Whether FBA could serve as a low-cost substitute for actigraphy in insomnia requires further investigation.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据