4.7 Article

Simultaneous microextraction of carbendazim, fipronil and picoxystrobin in naturally and artificial occurring water bodies by water-induced supramolecular solvent and determination by HPLC-DAD

期刊

JOURNAL OF MOLECULAR LIQUIDS
卷 297, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.molliq.2019.111897

关键词

Pesticides preconcentration; SUPRAS; 1-Decanol reverse micelles; Natural and artificial waters; High performance liquid chromatography

资金

  1. Coordenacao de Aperfeicoamento de Nivel Superior (CAPES) [3353/2014, 23038.007082/2014-03]
  2. Conselho Nacional de Desenvolvimento Cientifico e Tecnologico (CNPq) [481669/2013-2, 305552/2013-9, 307432/2017-3]
  3. Fundacao ArauCarla do Parana [163/2014]
  4. Instituto Nacional de Ciencia e Tecnologia de Bioanalitica (INCT) [573672/2008-3]
  5. Universidade Estadual de Londrina (UEL)
  6. Coordenacao de Aperfeicoamento de Pessoal de Nivel Superior - Brasil (CAPES) [001]

向作者/读者索取更多资源

Carbendazim, fipronil and picoxystrobin are pesticides widely utilized worldwide to enhance yield, improve quality and maximize economic returns of several cultures. However, due to potentially adverse effects to health and to ecosystems, their detection and monitoring in waters became a major concern. In this report, a new supramolecular solvent-based microe xtraction method, constituted of reverse micelles of 1-decanol arranged into a tetrahydrofuran/water medium, was developed to preconcentrate and monitor those pesticides in several natural and artificial waters by determination with High-Performance Liquid Chromatography - Diode Array Detector (HPLC-DAD). A 2(6-1) fractional factorial design with central point and Derringer-Suich desirability function were utilized to optimize the microextraction conditions. High preconcentration factors (21.43 to carbendazim, 71.10 to fipronil and 71.36 to picoxystrobin) and extraction factors (21.45 to carbendazim, 84.47% to fipronil and 83.00% to picoxystrobin) were obtained. The limits of detection (LOD), quantification (LOQ), the precision (RSD-relative standard deviation) and the accuracy (RE-relative error) of the developed method ranged between 0.23 and 0.45 mu g L-1, 0.78-1.50 mu g L-1, 1.65-6.53% and 0.11-6.00%, respectively. Recovery values obtained by applying the proposed method in spiked atmospheric water, groundwater, surface water and artificial water samples at mu g L-1 levels varied in the range of 93.5-110.0%. The quantification of fipronil in a natural sample water, in values higher than established by some international guidelines, reassures the importance of investigating and monitoring pesticides in natural and artificial waters. (C) 2019 Published by Elsevier B.V.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据