4.7 Article

Identification of IDH and TERTp mutation status using 1H-MRS in 112 hemispheric diffuse gliomas

期刊

JOURNAL OF MAGNETIC RESONANCE IMAGING
卷 51, 期 6, 页码 1799-1809

出版社

WILEY
DOI: 10.1002/jmri.26964

关键词

H-1-MRS; glioma; IDH; TERTp; machine learning

资金

  1. [TUBITAK 1003]
  2. [216S432]

向作者/读者索取更多资源

Background There is a growing interest in noninvasively defining molecular subsets of hemispheric diffuse gliomas based on the isocitrate dehydrogenase (IDH) and telomerase reverse transcriptase gene promoter (TERTp) mutation status, which correspond to distinct tumor entities, and differ in demographics, natural history, treatment response, recurrence, and survival patterns. Purpose To investigate whether metabolite levels detected with short echo time (TE) proton MR spectroscopy (H-1-MRS) at 3T can be used for noninvasive molecular classification of IDH and TERTp mutation-based subsets of gliomas. Study Type Retrospective. Subjects In all, 112 hemispheric diffuse gliomas (70 males/42 females, mean age: 42.1 +/- 13.9 years). Field Strength/Sequence Short-TE H-1-MRS (repetition time (TR) = 2000 msec, TE = 30 msec, number of signal averages = 192) and routine clinical brain tumor MR protocols were acquired at 3T. Assessment H-1-MRS data were quantified using LCModel software. TERTp and IDH1 or IDH2 (IDH1/2) mutations in the tissue were determined by either minisequencing or Sanger sequencing. Statistical Tests Metabolic differences between IDH mutant and IDH wildtype gliomas were assessed by a Mann-Whitney U-test. A Kruskal-Wallis test followed by a Tukey-Kramer test was used to analyze metabolic differences between IDH and TERTp mutational molecular subsets of gliomas. A Spearman rank correlation coefficient was used to assess the correlations of metabolite intensities with the Ki-67 index. Furthermore, machine learning was employed to classify the IDH and TERTp mutational status of gliomas, and the accuracy, sensitivity, and specificity values were estimated. Results Short-TE H-1-MRS classified the presence of an IDH mutation with 88.39% accuracy, 76.92% sensitivity, and 94.52% specificity, and a TERTp mutation within primary IDH wildtype gliomas with 92.59% accuracy, 83.33% sensitivity, and 95.24% specificity. Data Conclusion Short-TE H-1-MRS could be used to identify molecular subsets of hemispheric diffuse gliomas corresponding to IDH and TERTp mutations. Technical Efficacy Stage: 2 J. Magn. Reson. Imaging 2019.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据