4.3 Article

Effect of central hole location in phakic intraocular lenses on visual function under progressive headlight glare sources

期刊

JOURNAL OF CATARACT AND REFRACTIVE SURGERY
卷 45, 期 11, 页码 1591-1596

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jcrs.2019.06.022

关键词

-

资金

  1. Spanish Ministry of Economy and Competitiveness (Institute de Salud Carlos III) [RETICS RD16/008/0001]
  2. Junta de Castilla y Leon
  3. European Social Fund [EDU/1100/2017]

向作者/读者索取更多资源

Purpose: To analyze the effect of the central hole location in the V4c implantable collamer lens (ICL) on the quality of vision, including progressive headlight glare simulation and quality of life. Setting: IOBA-Eye Institute, Valladolid, Spain. Design: Case series. Methods: The central hole location was determined by slitlamp and dual Scheimpflug imaging for 6 months or more postoperatively. The visual acuity, mesopic contrast sensitivity, halogen glare contrast sensitivity, xenon glare contrast sensitivity, photostress recovery time after glare, de Boer scale, and Quality of Life Impact of Refractive Correction (QIRC) questionnaire results were evaluated. Multiple regression models were used to analyze the effect of the central hole location on parameters using the pupil center and visual axis as references based on Cartesian and polar coordinates. Results: The safety index was 1.13 and the efficacy index, 1.12. Under all testing circumstances, central hole decentration did not affect the visual acuity or contrast sensitivity. With the visual axis as a reference, worse QIRC values were associated with greater upward central hole displacement (P = .03) and a lower polar angle value (P = .008); also, halogen glare discomfort was greater with a higher radius (P = .04). Using the pupil center as a reference, greater nasal central hole decentration was associated with longer xenon glare photostress recovery time (P = .002). Conclusions: Implantation of the ICL with a central hole yielded excellent visual outcomes, even under increasing glare sources, regardless of the hole's location. However, hole decentration might affect patient-perceived quality of life, bothersome halogen glare, and longer xenon glare photostress recovery time. Such complaints after the early postoperative period might be managed with discrete ICL centration if the central hole is decentered upward or nasally. (C) 2019 ASCRS and ESCRS

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据