4.7 Article

Oxidation study of porous metal substrates for metal supported proton ceramic electrolyzer cells

期刊

CORROSION SCIENCE
卷 164, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.corsci.2019.108335

关键词

Porous metal supports; Proton ceramic electrolyzer cells; Ferritic stainless steel; Corrosion; Coating

资金

  1. Research Council of Norway (RCN) through the ENERGIX program [228819/E20, 268010/E20]

向作者/读者索取更多资源

Isothermal corrosion of coated and uncoated porous, ferritic stainless steel (Hoganas), with 20.6 wt% Cr and 30-35 % porosity, has been studied at temperatures from 600 to 800 degrees C in air and 2.5 %H2O/5 %H-2/Ar. Uncoated specimens form protective Cr2O3 scales following parabolic kinetics at 600 and 700 degrees C in air and at 800 degrees C in 2.5 %H2O/5 %H-2/Ar. Non protective scales were formed in 2.5 %H2O/5 %H-2/Ar at 600 and 700 degrees C and at 800 C in air. The coating overall improves the corrosion behavior. The scaling behavior was explained from Fe-Cr-O-2 stability diagrams and ratios between consumption and feed of Cr at the alloy-oxide interface.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据