4.7 Article

Performance assessment of specialist conductive paint for cathodic protection of steel in reinforced concrete structures

期刊

CONSTRUCTION AND BUILDING MATERIALS
卷 223, 期 -, 页码 1083-1094

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.conbuildmat.2019.07.344

关键词

Steel reinforced concrete; Conductive paint; Microstructure; Coating anode; Cathodic protection; Service life; Permeability; Polarization

向作者/读者索取更多资源

ICCP system provides effective corrosion protection in a chloride environment. This research evaluates the feasibility of zinc rich paints (ZRP) as ICCP anode for RC structures. The preliminary investigation showed the application of three layers of ZRP with medium concrete surface roughness and use of Cu/Nb/Pt wire as primary anode gives maximum bond strength and uniform current distribution across the ZRP coating. Moreover, polarization results showed satisfactory performance of the ZRP anode coating subjected to a current density of 12.5 mA/m(2). The anode was found to be vapour permeable and effectively provide protection with a service life of up to 15 years. (C) 2019 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据