4.1 Article

Hydroxyapatite ceramic implants for cranioplasty in children: a retrospective evaluation of clinical outcome and osteointegration

期刊

CHILDS NERVOUS SYSTEM
卷 36, 期 3, 页码 551-558

出版社

SPRINGER
DOI: 10.1007/s00381-019-04423-6

关键词

Bioceramics; Biomimetic; Cranioplasty; Custom-made prosthesis; Hydroxyapatite

向作者/读者索取更多资源

Introduction Cranioplasty in children is a controversial and challenging issue, since there is still no consensus on the ideal material. Main problems in paediatric age are represented by the child's growing skull, the lower bone thickness and the high incidence of cerebrospinal fluid (CSF) disorders or brain swelling. Autologous bone is still considered the gold standard. When it is not available, a wide range of alloplastic materials have been proposed. Hydroxyapatite, a ceramic-based derivative, bears a chemical composition very similar to the human natural bone, making this material a valuable alternative to other cranioplasty solutions. Methods All patients implanted with a custom-made porous hydroxyapatite device at Santobono-Pausilipon Hospital in Naples were retrospectively reviewed. A follow-up CT scan of the skull was performed from 1 up to 48 months postoperatively to document the bone ingrowth as well as the osteointegration process. The bone density was measured as according to the Hounsfield scale at the bone-implant interface. Results Between 2014 and 2018, 11 patients (7 males, 4 females) underwent cranioplasty with hydroxyapatite ceramic implants (HAP). Patients' age ranged between 3 and 16 years old. Initial aetiology was trauma in most cases. Two subjects were implanted with HAP as primary cranioplasty, 9 as revision surgery following previous cranioplasty failure. Sites of the cranial defect were unilateral fronto-temporo-parietal (N = 8), unilateral frontal (N = 1) and bifrontal (N = 2). Two patients with large bilateral defects received two prostheses. In one of these, the two prostheses were explanted and replaced with two back-up implants (accounting for a total of 15 implants in 11 patients). Osteointegration was measurable for 12 out of 15 implanted devices. The mean percentage was about 51%. There were six asymptomatic prosthesis fractures (40%), all occurring within 6 months from implant. In one case, the bifrontal prostheses were explanted and replaced. This was the only patient who underwent revision surgery. Conclusion Hydroxyapatite ceramic implants represent a valid alternative to other cranioplasty solutions. Where coaptation occurs correctly, with good osteointegration, implant mechanical resistance increases over time.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.1
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据