4.5 Article

Total knee arthroplasty using patient-specific instrumentation for osteoarthritis of the knee: a meta-analysis

期刊

BMC MUSCULOSKELETAL DISORDERS
卷 20, 期 1, 页码 -

出版社

BMC
DOI: 10.1186/s12891-019-2940-2

关键词

Total knee replacement; Total knee arthroplasty; Patient-specific instrumentation; Patient-matched instrumentation; Knee osteoarthritis; Patient-important outcome; Patient-reported outcome measure; Systematic review; Meta-analysis

向作者/读者索取更多资源

Background Total knee arthroplasty using patient-specific instrumentation (TKA-PSI), which are disposable cutting block guides generated to fit each patient's 3-dimensional knee anatomy, has been developed to treat patients with end-stage osteoarthritis of the knee. Surrogate markers such as radiographic malalignment have been well investigated, however, patient-important outcomes are not well examined to elucidate the efficacy of TKA-PSI. The aim of this review is to determine if TKA-PSI improves patient-reported outcome measures (PROM), surgery time, blood loss, transfusion and complications (e.g. surgical site infection, deep venous thrombosis, and revision TKA). Methods We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE, and ongoing clinical trials. For PROMs, surgery time, blood loss, and transfusion rate, we included randomized controlled trials (RCT) comparing TKA-PSI and standard TKA to treat osteoarthritis of the knee. For complications, we also included non-randomized comparative studies (non-RCT). Results This review includes 38 studies, 24 of which were RCT and 14 of which were non-RCT. These included a total of 3487 patients. The predominant population in the included studies highly reflected the general population, with 62% being female, aged over 60 and having end-stage osteoarthritis of the knee. TKA-PSI did not improve PROMs as compared to standard TKA for less than 1-year (mean difference 0.48, 95% confidence interval (CI) -1.92-0.97 in the Oxford knee score, mean 3-month follow-up) and for 1-year or more (mean difference 0.25, 95%CI - 4.39-4.89 in the WOMAC score, mean 29-month follow-up). TKA-PSI did not reduce surgery time (mean difference - 3.09 min, 95%CI -6.73-0.55). TKA-PSI decreased blood loss with a small effect size corresponding to a 0.4 g/dl hemoglobin decrease (95%CI 0.18-0.88), but did not decrease transfusion rate (risk difference - 0.04, 95%CI -0.09-0.01). TKA-PSI did not reduce complication rates (risk difference 0.00, 95%CI - 0.01-0.01 in the composite outcome). Conclusions TKA-PSI does not improve patient-reported outcome measures, surgery time, and complication rates as compared to standard TKA. TKA-PSI decreases blood loss with a small effect, which is not enough to reduce transfusion rate.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据