4.6 Article

Continuous-Flow Separation and Efficient Concentration of Foodborne Bacteria from Large Volume Using Nickel Nanowire Bridge in Microfluidic Chip

期刊

MICROMACHINES
卷 10, 期 10, 页码 -

出版社

MDPI
DOI: 10.3390/mi10100644

关键词

immunomagnetic separation; nickel nanowires bridge; large-volume sample; microfluidic chip; foodborne bacteria

资金

  1. National Natural Science Foundation of China [31802219]
  2. Walmart Foundation [SA17031161]

向作者/读者索取更多资源

Separation and concentration of target bacteria has become essential to sensitive and accurate detection of foodborne bacteria to ensure food safety. In this study, we developed a bacterial separation system for continuous-flow separation and efficient concentration of foodborne bacteria from large volume using a nickel nanowire (NiNW) bridge in the microfluidic chip. The synthesized NiNWs were first modified with the antibodies against the target bacteria and injected into the microfluidic channel to form the NiNW bridge in the presence of the external arc magnetic field. Then, the large volume of bacterial sample was continuous-flow injected to the channel, resulting in specific capture of the target bacteria by the antibodies on the NiNW bridge to form the NiNW-bacteria complexes. Finally, these complexes were flushed out of the channel and concentrated in a lower volume of buffer solution, after the magnetic field was removed. This bacterial separation system was able to separate up to 74% of target bacteria from 10 mL of bacterial sample at low concentrations of <= 10(2) CFU/mL in 3 h, and has the potential to separate other pathogenic bacteria from large volumes of food samples by changing the antibodies.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据